GENERAL INFORMATION
BASIC PULSE CONTROL
This instrument can be triggered by its own internal clock or by an external TTL trigger
signal. In either case, two output channels respond to the trigger: HV PULSE and
SYNC. The HV PULSE channel is the signal that is applied to the DUT. Its amplitude is
fixed, but the polarity is switchable. The SYNC pulse is a fixed-width TTL-level
reference pulse used to trigger oscilloscopes or other measurement systems. When the
delay is set to a positive value the SYNC pulse precedes the HV PULSE pulse. When
the delay is set to a negative value the SYNC pulse follows the HV PULSE pulse.
These pulses are illustrated below, assuming internal triggering, a positive delay, and
positive amplitude:
If the delay is negative, the order of the SYNC and OUT pulses is reversed:
29
SYNC OUT
(generated by the
internal oscillator)
100 ns, FIXED
HV PULSE
3V, FIXED
PULSE
WIDTH
(1-20us)
DELAY > 0
(VARIABLE)
AMPLITUDE,
-1.5 or +1.5 kV
TYPICALLY
RISE TIME,
VARIABLE
FALL TIME
(NOT
VARIABLE)
SYNC OUT
(generated by the
internal oscillator)
100 ns, FIXED
HV PULSE
3V, FIXED
PULSE
WIDTH
(1-20us)
DELAY < 0
(VARIABLE)
RISE TIME,
VARIABLE
FALL TIME
(NOT
VARIABLE)
AMPLITUDE,
-1.5 or +1.5 kV
TYPICALLY
Содержание AVRQ-5-B
Страница 52: ...Bottom side 52 ...
Страница 56: ...Top side Bottom side A P6246 differential probe was used to observe the logic outputs in the TLP2366 tests 56 ...
Страница 57: ...PCB 299B FOR ADUM241E0BRWZ 57 ...
Страница 82: ...PCB 158R2 LOW VOLTAGE POWER SUPPLY ...
Страница 87: ...DUT WIRING ON STANDARD DAUGHTERBOARD PCB 267C ...
Страница 88: ...DUT WIRING ON CUSTOMIZED TLP2366 DAUGHTERBOARD PCB 298B ...
Страница 89: ...DUT WIRING ON CUSTOMIZED ADUM241E0BRWZ DAUGHTERBOARD PCB 299B ...
Страница 91: ...PERFORMANCE CHECK SHEET 91 ...