- 24 -
E
N
G
TERMINAL BLOCK
-
Power negative
+
12 V power positive =
C
Alarm contact of the sensor with capacity of 100 mA
Normally closed sensor idle
NC
T
Anti-tampering contact of the sensor with capacity of 100 mA
Normally closed
T
SW1 - BALANCING RESISTANCES
DIP
1
TAMPER
(see S1)
ON
10 kohm resistance inserted
OFF
DEFAULT
10 kohm resistance excluded
DIP
2
TAMPER
(see S1)
ON
5.6 kohm resistance inserted
OFF
DEFAULT
5.6 kohm resistance excluded
DIP
3
TAMPER
(see S1)
ON
4.7 kohm resistance inserted
OFF
DEFAULT
4.7 kohm resistance excluded
DIP
4
TAMPER
(see S1)
ON
2.2 kohm resistance inserted
OFF
DEFAULT
2.2 kohm resistance excluded
DIP
5
ALARM
(in parallel)
ON
10 kohm resistance inserted
OFF
DEFAULT
10 kohm resistance excluded
DIP
6
ALARM
(in parallel)
ON
5.6 kohm resistance inserted
OFF
DEFAULT
5.6 kohm resistance excluded
DIP
7
ALARM
(in parallel)
ON
4.7 kohm resistance inserted
OFF
DEFAULT
4.7 kohm resistance excluded
DIP
8
ALARM
(in parallel)
ON
2.2 kohm resistance inserted
OFF
DEFAULT
2.2 kohm resistance excluded
S1 MANAGING THE TAMPER CONTACT
1 - 2
The resistance, configurable via DIP SWITCHES 1, 2, 3 and 4 of SW1, is in
series between the
ALARM
contact and that of the
TAMPER
(DEFAULT)
2 - 3
The resistance, configurable via DIP SWITCHES 1, 2, 3 and 4 of SW1, is in
parallel with the
TAMPER
contact
It is possible to insert balancing resistances for both the alarm and tamper contacts.
For the settings, refer to the tables for
S1
and
SW1
.
SW2 - FUNCTIONS
DIP 1
ON
DEFAULT
Led Enable
OFF
Led Excluded
DIP 2
ON
Anti-mask
active
Tamper relay
OFF
DEFAULT
Anti-mask
active
Alarm relay
DIP 3
ON
Anti-mask
Microwave Active (Model OnE DT only)
OFF
DEFAULT
Anti-mask
Microwave Disabled (Model OnE DT only)
DIP 4
OFF
DEFAULT
In this configuration the infrared has a
default sensitivity
(designed for classic use) and
performs a digital
analysis of the signal
.
DIP 5
OFF
DIP 4
ON
LOW
In this configuration the infrared has a
low sensitivity
compared to the default and performs a
digital
analysis of the signal
that is
stricter
than the default and considers a
double pulse
DIP 5
OFF
DIP 4
OFF
MEDIA
In this configuration the infrared has a
average sensitivity compared to the default
and
performs a
digital analysis
of the signal that is stricter than the default
DIP 5
ON
DIP 4
ON
HIGH
In this configuration the infrared has
high sensitivity
and detects
any signal
by analyzing the
amplitude
DIP 5
ON
DIP 6
ON
Yellow LED
displays status of the
Microwave (Model OnE DT only)
OFF
DEFAULT
Yellow LED
displays status of the
Anti-mask
DIP 7
ON
Anti-mask
Infrared Active
OFF
DEFAULT
Anti-mask
Infrared Disabled
DIP 8
ON
Tamper
Accelerometer
enabled
OFF
DEFAULT
Tamper
Accelerometer
excluded
OnE PA e OnE DT
O
N
1
2
3
4
5
6
7
8
O
N
1
2
3
4
5
6
7
8
SW1
SW2
S1
1
3
- +
C NC
T
1
T
2
RV1
RV2
TAMPER
L1
L2
2
CONNECTIONS WITH S1 in
position 1 - 2
If a TAMPER resistance is inserted
in series using DIPs 1, 2, 3 and 4
of SW1, terminal blocks NC and
T2 must not be used
O
N
O
N
1
2
3
4
5
6
7
x x
- +
L
L
S1
NOTE: When you simultaneously set more than one of DIPs 1, 2, 3 and 4 (Tamper) to ON, the relative heating elements
will be placed in parallel with each other. The same principle applies to DIPs 5, 6, 7 and 8 (Alarm)
Содержание ONE DT
Страница 11: ... 11 I T A ...
Страница 12: ... 12 I T A ...
Страница 13: ... 13 I T A ...
Страница 27: ... 27 E N G ...
Страница 28: ... 28 E N G ...
Страница 29: ... 29 E N G ...
Страница 43: ... 43 F R A ...
Страница 44: ... 44 F R A ...
Страница 45: ... 45 F R A ...
Страница 59: ... 59 E S P ...
Страница 60: ... 60 E S P ...
Страница 61: ... 61 E S P ...
Страница 75: ... 75 N L D ...
Страница 76: ... 76 N L D ...
Страница 77: ... 77 N L D ...