MSC C10M-BT / MSC C10M-BTC
User Manual
50 / 90
Feature
Options
Description
Stop Bits
1,2
Stop bits indicate the end of a serial
data packet. (A start bit indicates the
beginning). The standard setting is 1
stop bit. Communication with slow
devices may require more than 1 stop
bit.
Flow Control
None, Hardware RTS/CTS,
Flow control can prevent data loss
from buffer overflow. When sending
data, if the receiving buffers are full, a
'stop' signal can be sent to stop the
data flow. Once the buffers are empty,
a 'start' signal can be sent to re-start
the flow. Hardware flow control uses
two wires to send start/stop signals.
VTUF8 Combo Key
Support
Enabled, Disabled,
Enable VT-UF8 Combination Key
Support for ANSI/VT100 terminals
Recorder Mode
Disabled, Enabled
With this mode enabled only text will
be sent. This is to capture Terminal
data.
Resolution 100x31
Disabled, Enabled
Enables or disables extended terminal
resolution
Legacy OS Redirection
80x24, 80x25
On Legacy OS, the number of rows
and Columns supported redirection
Putty KeyPad
VT100, Linux, XTERMR6,
SCO, ESCN, VT400
Select FunctionKey and KeyPad on
Putty.
Redirection after BIOS
POST
Always Enable, Bootloader
The Settings specify if BootLoader is
selected then Legacy console
redirection is disabled before booting
to Legacy OS. Default value is Always
Enable which means Legaacy console
Redirection is enabled for Legacy OS.
6.7.6 CPU Configuration
Note: Dependent on used CPU, available setup options may vary
Feature
Options
Description
Socket 0 Information
Submenu
Shows different informations about the
CPU such as CPU Signature,
Microcode Patch etc.
Limit CPUID Maximum
Enabled
Disabled
Limit the maximum input value for the
CPUID instruction to 2. Enable this as
a workaround for old OS that cannot
handle Pentium III or newer CPUs.
Execute Disable Bit
Enabled
Disabled
XD can prevent certain classes of
malicious buffer overflow attacks when
combined with a supporting OS
Intel
®
Virtualization
Technology
Enabled
Disabled
When enabled, a VMM can utilize the
additional hardware capabilities
provided by Vanderpool Technology
For more information see also
technotes in Chapter 8.
Содержание COM Express MSC C10M-BT
Страница 10: ...MSC C10M BT MSC C10M BTC User Manual 10 90 Block diagram ...
Страница 11: ...MSC C10M BT MSC C10M BTC User Manual 11 90 ...
Страница 13: ...MSC C10M BT MSC C10M BTC User Manual 13 90 A B Trusted Platform Modules 0 1 1 1 optional TPM 1 2 module ...
Страница 33: ...MSC C10M BT MSC C10M BTC User Manual 33 90 A64 PCIE_TX1 B64 PCIE_RX1 A64 PCIE_TX1 B64 PCIE_RX1 ...