CMD

Description

Default value

Pc01

End of Alarm (EOA)

-

Pc02

Reset of Alarm (ROA)

-

Pc03

Firmware Version

-

Pc06

Device Status

-

Pc07

Direct the first alarm call to DCP telephone (0 =No, 1= Yes)

0

Pc08

Alarm call bypass filter time (0-10 s)

10

Pc09

Reset to Factory Default

1234567890

Pc10

Reboot Digital Audio Unit

1234567890

Pc11

Alarm Button Countdown timer (seconds)

3

Pc12

Alarm Filter Input (0=Off ; 1=On)

1

Pc13

Cancel alarm by pressing alarm button (0=Off ; 1=On)

0

Pc14

Wait for Alarm Acknowledgment (0=Off ; 1=On)    *                      

1

Pc15

Automatic End of Alarm EOA (0=Off ; 1=On)

0

Pc16

Privacy Mode ** (0= Off, 1= On)

1

Pc17

Type of cabin alarm button (0= n/o; 1=n/c)

0

Pc18

Type of maintenance alarm button (0= n/o; 1= n/c)

0

Pc19

Type of end of alarm button (EOA) (0= n/o; 1=n/c)

0

Pc21

LED Mode (0=Full ; 1=EN81-28)

1

Pc22

Alarm Call Retry Attempts

5

Pc23

Maintenance Call Retry Attempts

3

Pc24

Lift Car Microphone Volume

5

Pc25

Lift Car Speaker Volume

5

Pc26

Lift Car Announcement Volume 

5

Pc27

Floor voice synthesis

1

Pc28

Language ***

(1=Spanish;2=Portuguese;3=Italian;4=English;5=German;6=French)

400000

Pc29

Time between alarm calls (in seconds)

0

Pc32

Extended Address

00

Pc33

Battery check enabled

1

c

 

= number of the car you need to check/ configure

*If the Alarm Acknowledgement is on, the Operator must press “0” to acknowledge the alarm. 
**The microphone inside the car is disconnected if there’s no emergency alarm call.
***The DAU can use up to six simultaneous languages, each digit being its sequence order.  

The table below indicates all the parameters which can be set on the DAU:

Содержание AC-DAB10-120-F-0L-000

Страница 1: ...Part No AC DAB10 120 F 0L 000 Typical CAN DAU LPBus System Architecture In the Box DAU unit Connector P 3 5 H 4V x1 Connector P 3 5 H 6V x1 Mounting Clip x2 Multi Product Installation guide Connector...

Страница 2: ...3 The DAU can be installed with 2 or 4 wires 2 wires uses CAN H and CAN L to reduce interference problems with the DAU LPBus and requires an external power supply between 8 28VDc 250mA while 4 wires...

Страница 3: ...speaker default Internal SW2 Battery Battery Config Enabled Disabled default Disabled SW1 DAU configurations See chapter DAU configurations Only for contacts without voltage Place an intermediate rela...

Страница 4: ...ces are connected to DAU apart from DCP CONNECTION TO CANBUS When installing a DAU connect the unit or the CAN Bus Splitter to J8 using a 4 core cable a CAN Bus Splitter is required when a DCP is supp...

Страница 5: ...connector as can be seen in the wiring diagram on page 2 The following table describes the operation of the two LEDs green and yellow on the DAU Yellow LED Green LED FUNCTION OFF OFF End of alarm or...

Страница 6: ...ration of the DCP You can modify or check several parameters in each SMS by separating them with commas If the DCP doesn t have access to voice call yellow and green LEDs will both flash until the iss...

Страница 7: ...n 0 n o 1 n c 0 Pc19 Type of end of alarm button EOA 0 n o 1 n c 0 Pc21 LED Mode 0 Full 1 EN81 28 1 Pc22 Alarm Call Retry Attempts 5 Pc23 Maintenance Call Retry Attempts 3 Pc24 Lift Car Microphone Vol...

Страница 8: ...8 DIMENSIONS...

Страница 9: ...e lid of the DAU disconnecting the existing battery and replacing it with the new battery from Avire the part number is on the battery label This battery should be properly recycled and not disposed o...

Отзывы: