7
CMD
Description
Default value
Pc01
End of Alarm (EOA)
-
Pc02
Reset of Alarm (ROA)
-
Pc03
Firmware Version
-
Pc06
Device Status
-
Pc07
Direct the first alarm call to DCP telephone (0 =No, 1= Yes)
0
Pc08
Alarm call bypass filter time (0-10 s)
10
Pc09
Reset to Factory Default
1234567890
Pc10
Reboot Digital Audio Unit
1234567890
Pc11
Alarm Button Countdown timer (seconds)
3
Pc12
Alarm Filter Input (0=Off ; 1=On)
1
Pc13
Cancel alarm by pressing alarm button (0=Off ; 1=On)
0
Pc14
Wait for Alarm Acknowledgment (0=Off ; 1=On) *
1
Pc15
Automatic End of Alarm EOA (0=Off ; 1=On)
0
Pc16
Privacy Mode ** (0= Off, 1= On)
1
Pc17
Type of cabin alarm button (0= n/o; 1=n/c)
0
Pc18
Type of maintenance alarm button (0= n/o; 1= n/c)
0
Pc19
Type of end of alarm button (EOA) (0= n/o; 1=n/c)
0
Pc21
LED Mode (0=Full ; 1=EN81-28)
1
Pc22
Alarm Call Retry Attempts
5
Pc23
Maintenance Call Retry Attempts
3
Pc24
Lift Car Microphone Volume
5
Pc25
Lift Car Speaker Volume
5
Pc26
Lift Car Announcement Volume
5
Pc27
Floor voice synthesis
1
Pc28
Language ***
(1=Spanish;2=Portuguese;3=Italian;4=English;5=German;6=French)
400000
Pc29
Time between alarm calls (in seconds)
0
Pc32
Extended Address
00
Pc33
Battery check enabled
1
c
= number of the car you need to check/ configure
*If the Alarm Acknowledgement is on, the Operator must press “0” to acknowledge the alarm.
**The microphone inside the car is disconnected if there’s no emergency alarm call.
***The DAU can use up to six simultaneous languages, each digit being its sequence order.
The table below indicates all the parameters which can be set on the DAU:
Содержание AC-DAB10-120-F-0L-000