J1

Vout

Common output (5VDC/ Batt)

Alarm 1

Cabin alarm button *

Alarm 2

Maintenance alarm button*

Filter

Alarm filter *

Vout

Common output (5VDC/ Batt)

EOA

End of Alarm signal input

J2

LPBus

Low Power Bus (LPBus) which connects to external audio units and other LPBUS devices

J6

Trace

Required for debugging (only for Avire Technical Support)

J9

+Vin (8-28 VDC)

2-Wire System: 8-28VDC 250mA max from external power supply. CAN H and CAN L communication 
connected to the DCP.

4-Wire System: Connection from  DCP/CANBus Splitter. Power supply is not required, as DAU LPBus will 
receive its power from DCP/ CANBus Splitter.

It is recommended to use twisted pair wiring for CAN H and CAN L.

CAN H

CAN L

-Vin (Ground)

J10

Green

Pictogram

Please Note: 2 outputs of 12Vdc or 24Vdc are 
supplied with a max current of 20mA each. The 
output voltage can be selected using the SW5 
switch located inside the device (default: 12Vdc). 
It is possible to connect any type of indicator that 
doesn’t exceed these specifications.

Yellow

Pictogram

Ground

Negative reference

J11

MIC +

External microphone connections. Please only use microphones approved by Avire.

MIC -

SPK +

External speaker connections. Please only use speakers approved by Avire.

SPK -

SW4

Microphone Config 

Internal/External microphone (default: Internal)

SW3

Speaker Config 

Internal/External speaker (default: Internal)

SW2

Battery

Battery Config (Enabled/Disabled) (default: Disabled) **

SW1

DAU configurations

See chapter DAU configurations

* - Only for contacts without voltage. Place an intermediate relay if any button has voltage.

** - In installations where the DAU is powered from a power supply that also has a battery backup, its internal battery may 
be disconnected. In all other cases the battery should be connected, otherwise the system won’t work in the case of mains 
power failure.

Note: Connections use a positive 5vdc common and all DAU programming is done via the DCP

End of Alarm (EOA): This indicates that the emergency lift trapping rescue is over and the alarm can 
be turned off or reset.

Alarm Filter: The Cabin Alarm button will not activate unless the lift is in a fault condition or the 
doors are closed, this filter is mostly used to prevent nuisance calls. DAU LPBus does not need to 
be programmed but requires the lift signals.

Maintenance Alarm Button: This allows dialling of a different telephone number if a trapped person 
is a member of maintenance staff (SOS number requires programming via the DCP, P030)

Cabin Alarm button: This is the main alarm button in the car operating panel which needs a voltage 
free contact from the Alarm push to trigger an emergency Alarm call. The button is defaulted to 
Normally Open, but can be reconfigured to Normally Closed (see programming guide DAU below 
PC117)

LPBus (Low Power Bus): This connector allows the connection of Triphony and Inductive loop 
units. 

Содержание AC-DAB10-120-F-0L-000

Страница 1: ...Part No AC DAB10 120 F 0L 000 Typical CAN DAU LPBus System Architecture In the Box DAU unit Connector P 3 5 H 4V x1 Connector P 3 5 H 6V x1 Mounting Clip x2 Multi Product Installation guide Connector...

Страница 2: ...3 The DAU can be installed with 2 or 4 wires 2 wires uses CAN H and CAN L to reduce interference problems with the DAU LPBus and requires an external power supply between 8 28VDc 250mA while 4 wires...

Страница 3: ...speaker default Internal SW2 Battery Battery Config Enabled Disabled default Disabled SW1 DAU configurations See chapter DAU configurations Only for contacts without voltage Place an intermediate rela...

Страница 4: ...ces are connected to DAU apart from DCP CONNECTION TO CANBUS When installing a DAU connect the unit or the CAN Bus Splitter to J8 using a 4 core cable a CAN Bus Splitter is required when a DCP is supp...

Страница 5: ...connector as can be seen in the wiring diagram on page 2 The following table describes the operation of the two LEDs green and yellow on the DAU Yellow LED Green LED FUNCTION OFF OFF End of alarm or...

Страница 6: ...ration of the DCP You can modify or check several parameters in each SMS by separating them with commas If the DCP doesn t have access to voice call yellow and green LEDs will both flash until the iss...

Страница 7: ...n 0 n o 1 n c 0 Pc19 Type of end of alarm button EOA 0 n o 1 n c 0 Pc21 LED Mode 0 Full 1 EN81 28 1 Pc22 Alarm Call Retry Attempts 5 Pc23 Maintenance Call Retry Attempts 3 Pc24 Lift Car Microphone Vol...

Страница 8: ...8 DIMENSIONS...

Страница 9: ...e lid of the DAU disconnecting the existing battery and replacing it with the new battery from Avire the part number is on the battery label This battery should be properly recycled and not disposed o...

Отзывы: