AVIRE AC-DAB10-120-F-0L-000 Скачать руководство пользователя страница 2

2

INTRODUCTION

1. 

The Digital Audio Unit (AC-DAB10-120-F-0L-000) connects with the Digital Communication 
Platform (DCP) to provide a 2-way communication point in the lift car. 

2. 

The DAU is mounted behind the lift car operating panel (COP) and connected to the machine 
room mounted DCP via a 2 or 4 wire digital CAN Bus, providing stable communication over 
trailing cables of up to 200m.

3. 

The DAU can be installed with 2 or 4 wires: 2 wires uses CAN H and CAN L to reduce interference 
problems with the DAU LPBus and requires an external power supply between 8-28VDc 250mA, 
while 4 wires means no external power supply is needed because the DCP will supply the power 
required by the DAU LPBUS.

4. 

It is recommended that customers use shielded twisted pair cable to ensure minimal disruption 
to the audio channel from ambient electrical noise in the travelling cable.

CONNECTORS

*

*

* Connect to external power supply for 2-wire system & to DCP for 4-wire system installations. 

Содержание AC-DAB10-120-F-0L-000

Страница 1: ...Part No AC DAB10 120 F 0L 000 Typical CAN DAU LPBus System Architecture In the Box DAU unit Connector P 3 5 H 4V x1 Connector P 3 5 H 6V x1 Mounting Clip x2 Multi Product Installation guide Connector...

Страница 2: ...3 The DAU can be installed with 2 or 4 wires 2 wires uses CAN H and CAN L to reduce interference problems with the DAU LPBus and requires an external power supply between 8 28VDc 250mA while 4 wires...

Страница 3: ...speaker default Internal SW2 Battery Battery Config Enabled Disabled default Disabled SW1 DAU configurations See chapter DAU configurations Only for contacts without voltage Place an intermediate rela...

Страница 4: ...ces are connected to DAU apart from DCP CONNECTION TO CANBUS When installing a DAU connect the unit or the CAN Bus Splitter to J8 using a 4 core cable a CAN Bus Splitter is required when a DCP is supp...

Страница 5: ...connector as can be seen in the wiring diagram on page 2 The following table describes the operation of the two LEDs green and yellow on the DAU Yellow LED Green LED FUNCTION OFF OFF End of alarm or...

Страница 6: ...ration of the DCP You can modify or check several parameters in each SMS by separating them with commas If the DCP doesn t have access to voice call yellow and green LEDs will both flash until the iss...

Страница 7: ...n 0 n o 1 n c 0 Pc19 Type of end of alarm button EOA 0 n o 1 n c 0 Pc21 LED Mode 0 Full 1 EN81 28 1 Pc22 Alarm Call Retry Attempts 5 Pc23 Maintenance Call Retry Attempts 3 Pc24 Lift Car Microphone Vol...

Страница 8: ...8 DIMENSIONS...

Страница 9: ...e lid of the DAU disconnecting the existing battery and replacing it with the new battery from Avire the part number is on the battery label This battery should be properly recycled and not disposed o...

Отзывы: