30
Click "
Save
". Settings will take effect after the message "saved successfully" shows.
4.2.6 Network configuration
1) Network Port
Data Port:
set the data port. Device will restart automatically after the port setting being changed (default: 3000,
other options: 0-65535).
Web Port
: set the web port. Device will restart automatically after the port setting being changed (default: 80, other
options: 0-65535).
Onvif Port:
set the Onvif port. Device will restart automatically after the port setting being changed (default: 2000,
other options: 0-65535).
Soap Port:
set the soap port (default: 1936, other options: 0-65535).
RTMP Port:
set the RTMP port (default: 1935, other options: 0-65535).
RTSP Port:
set the RTSP port. Device will restart automatically after the port setting being changed (default: 554,
other options: 0-65535).
Visca Port:
set the Visca port. Device will restart automatically after the port setting being changed (default: 3001,
other options: 0-65535).
Click "
Save
". Settings will take effect after the message "saved successfully" shows.
RTMP Obtaining Path:
rtmp: // device IP address:1935 / live / av0 (av0 main stream; av1 secondary stream).
2) Ethernet Parameters
DHCP:
enable/disable obtaining IP automatically. Save changes and reboot the device for the changes to takes
effect (default: OFF).
IP Address:
set IP address. Save changes and reboot the device for the changes to takes effect (default:
192.168.5.163).
Note:
this IP address is the same as the one used for login Web page.
Subnet Mask:
set the subnet mask (default: 255.255.5.0).
Default Gateway:
set the default gateway (default: 0.0.0.0).
Physical Address:
set the physical address (the parameter is read-only and cannot be modified).
Click "
Save
". Settings will take effect after the message "saved successfully" shows.
Note:
need to prevent IP conflicts when modify.
3) DNS Parameters
Preferred DNS Server: set the preferred DNS server (default: 0.0.0.0).
Alternate DNS Server: alternate DNS server settings (default 0.0.0.0).
Click "
Save
". Settings will take effect after the message "saved successfully" shows.
4) GB28181
Switch:
set whether or not open GB28181.
Time Synchronization:
set whether or not synchronize time.
Stream Type:
stream type setting (default: main stream, other options: secondary stream).
Sign Effective Time (seconds):
default: 3600, other options: range: 5-65535.
Heartbeat Time (seconds):
default: 60, other options: range: 1-65535.
Register ID:
34020000001320000001
Register User Name:
IPC
Register Password:
12345678
Equipment Ownership:
users can add their own.
Содержание AV-1364