EN
9
F - OPERATION WITH THE APP
1 - INDICATOR LIGHT
Normal
operation
The LED indicator
flashes red
once every
40 seconds.
---
Smoke/heat
detection
The alarm sounds.
and the LED
indicator
flashes red
without stopping
until smoke has
been evacuated
Evacuate smoke
or heat.
Low battery
alert
The alarm beeps
briefly every
40 seconds and
the LED indicator
flashes.
Do one of
the following:
• Replace the
battery.
• Press the
test button to
pause the alarm
for 8 hours.
Failure
The alarm beeps
briefly every
40 seconds.
Replace
the device.
Alarm test
The alarm must be tested once a week to make
sure it is working correctly. If the alarm test fails,
replace the batteries and/or the smoke detector.
- Press and hold the test button for 5 seconds.
The alarm sounds.
- Release the test button.
Mute function
If the alarm sounds in error while cooking, it can
be paused for 10 minutes by pressing the test
button. The LED indicator flashes once every 8
seconds. Locate the alarm source before using
the mute function to make sure it is not a life-
threatening situation.
2 - CONNECTION
2.1 - INSTALLING THE MOBILE APP AND
CREATING AN ACCOUNT
This product only works with a 2.4Ghz frequency.
During pairing, make sure your smartphone is
connected on that specific frequency. If you are
not sure, check with your Internet service provider.
Once the smoke detector has been installed,
follow the instructions below to pair it.
Download the Avidsen Home app from the
Android Play Store or Apple App Store.
Launch the app and log in if you already have
an account. If not, press CREER UN NOUVEAU
COMPTE (CREATE A NEW ACCOUNT) and let the
application guide you.
WIFI-CONNECTED SMOKE DETECTOR
Содержание 127065
Страница 15: ......
Страница 16: ...Avidsen 19 avenue Marcel Dassault ZAC des Deux Lions 37200 Tours France ...