EN
49
F - MAINTENANCE AND UPKEEP
2.1 - EVENT LOG AND ERROR CODES
• During operation, events may occur that may be
malfunctions of the motor drive or consequences
of user actions.
• Each event has a different code.
• This code is displayed by a combination of red
LEDs that are on, off or flashing on the
MENU 0
display.
• When
OK
or
PROG
are pressed, this code is
deleted. However, the last 4 codes generated
are memorised, and can be viewed in a log.
• To access them, press
OK
twice, then use
the “
+
” and “
–
” buttons to scroll through the
memorised codes.
To diagnose any problems, here is the list of codes
and their meaning:
: LED
off
: LED
on
:
Flashing
LED
There are two types of code: Error (
E
) or
Information (
I
). N.B. an error requires action from
the installer to correct the motor drive problem.
LED
Description
Type
L1 L2 L3 L4
An obstacle has
been detected in M1
when closing.
I
L1 L2 L3 L4
An obstacle has
been detected in M2
when closing.
I
L1 L2 L3 L4
The photocell beam
has been obstructed.
I
L1 L2 L3 L4
An obstacle has
been detected in M1
when opening.
I
L1 L2 L3 L4
An obstacle has
been detected in M2
when opening.
I
L1 L2 L3 L4
Motor M1 is not
connected or
incorrectly connected
(contact failure).
Check connections.
E
L1 L2 L3 L4
Motor M2 is not
connected or
incorrectly connected
(contact failure).
Check connections.
E
L1 L2 L3 L4
The maximum
operating time has
been reached (a
motor is idle and the
stop has not been
reached?). Check
that the motor is
engaged.
E
L1 L2 L3 L4
Panel M1 closed
before panel M2.
Increase the time
interval between the
movement of both
panels.
E
L1 L2 L3 L4
Three
obstacles detected
in a row during
opening. Check
the gate movement
area.
E
L1 L2 L3 L4
Three obstacles
detected in a row
during closing.
Check the gate
movement area.
E
L1 L2 L3 L4
The main power
supply has been cut
during a movement
phase OR the battery
is too weak for
proper
operation.
E
L1 L2 L3 L4
Self-learning is
not valid (it was
never performed
or a setting that
requires repetition
of self-learning has
been changed). Start
self-learning.
E
L1 L2 L3 L4
Automatic closure
has been cancelled.
Generated if the gate
re-opens 3 times (10
in collective mode)
after a photocell has
been obstructed
during automatic
closure OR if the
beam was obstructed
for more than 3
minutes.
E
L1 L2 L3 L4
The gate control
input (2B) is
permanently
earthed. Check the
connections.
E
CONNECTED MOTOR DRIVE KIT WITH ACTUATORS