EN
30
D - BEGINNING OPERATION
Acceleration
OK
PROG
Acceleration settings
+ : increases acceleration
– : decreases acceleration
OK
MENU 0
adjustable from
0 to4
Stop tolerance
OK
PROG
Adjustable tolerance
+ : increases tolerance
– : decreases tolerance
OK
MENU 0
adjustable from 0 to 4
* this change requires a new self-learning procedure
Type of gate
Photocell mode
OK
PROG
Type of gate
–and+ to set the value
OK
MENU 0
OK
PROG
Photocell mode
–and+ to set the value
OK
MENU 0
0 : inactive when the opening process starts
(by default)
1 : active when the opening process starts
0 : 2-panel swing gate
(by default)
1 : 1-panel swing gate (door)
–
+
+
–
+
–
L1
L2
L3
L4
L1
L2
L3
L4
L1
L2
L3
L4
L1
L2
L3
L4
L1
L2
L3
L4
L1
L2
L3
L4
L1
L2
L3
L4
L1
L2
L3
L4
Save setting
*
L1
L2
L3
L4
Save setting
L1
L2
L3
L4
Save setting
*
L1
L2
L3
L4
Save setting
*
L1
L2
L3
L4
3.2.1. ACCELERATION/DECELERATION AT
END OF TRAVEL
The acceleration at the start of the panel opening
process can be adjusted from a level of 0 to 4. The
higher this value, the more time the gate will take
to reach its nominal speed. The default level is 3,
at which the gate takes about 4 seconds to open.
It may be useful to reduce the acceleration for a
softer start.
To adjust the acceleration, follow the procedure
below
• Press PROG for 3 seconds. L0 will flash once
and L1 will turn on.
• Press PROG for 3 seconds. L0 will flash twice.
• Press OK and the number of LEDs that turn on
will indicate the set value.
• Use the “–” and “+” buttons to change this value.
• Press OK to confirm this value. All the LEDs will
turn on and off to confirm the operation.
NOTE: If the acceleration setting is changed,
self-learning must be repeated.
3.2.2. PHOTOCELL MODE
The photocells are active when the panels close
because they are placed between the posts (pair
1) to secure the passage between panels.
The installation of a second set of photocells is
useful to completely protect the gate movement
area during closing and before opening:
Inner side of the property
view from above
pair 2
pair 1
RX1
RX2
TX1
TX2
In that case, the system must verify that its infrared
beam is not obstructed before starting to open the
panels. But by default, photocells are only tested
during closure.
To activate or deactivate photocells at the
beginning of the opening process, follow the
procedure below
• Press “
PROG
” for 3 seconds. L0 will flash once
and L1 will turn on.
• Press
PROG
for 3 seconds. L0 will flash twice.
• Press “+” once. L2 will turn on instead of L1.
• Press
OK
.
• If L1 is off, the photocells are inactive at the
beginning of the opening process. Press “+” to
activate them, then
OK
to confirm. All LEDs will
turn on and off to confirm the operation.
• If L1 is on, the photocells are active at the
beginning of the opening process. Press “–” to
deactivate them, then
OK
to confirm. All LEDs
will turn on and off to confirm the operation.
CONNECTED MOTOR DRIVE KIT WITH ACTUATORS