6
Every time, you change the EDID data, all the displays will be blank for 3 seconds. The RS232
port will send out the feedback code.
No.
EDID management
Solution
RS232 command
(ASCII, 9600bps. 8N1)
The Operation of Front Panel Buttons
1
Factory Default
Management Setting
EDIDMInit.
Press the buttons:
“←”
+
“
AV
”
+
“
INPUT1
”
+
“
UNDO
”
2
Auto EDID Manage
EDIDMAuto.
Press the buttons:
“←”
+
“
AV
”
+
“
INPUT2
”
+
“
UNDO
”
3
Manually EDID Switching
EDIDM[X]B[Y].
Null
NOTICE: there is a “.” behind the command, which is easy to miss.
6.1. Auto EDID Management
When you are running the auto-EDID management by RS232 command or front panel operation, it will
copy the EDID data from the most priority display.
The priority principle:
HDMI/DVI OUTPUTS Priority
1
High priority
2
3
4
5
6
7
8
Low priority
The most priority port is output 1.