AVG-TMX44PRO
Command
Function
Feedback
Example
EDIDMInit.
Restore the factory default EDID data
of every input.
EDIDMInit.
EDIDM[X]B[Y].
Manual EDID switching. Enable
input[Y] to learn the EDID data of
output[X]. If the EDID data is not
available, then set it to initial EDID
data.
EDIDM[X]B[Y]
EDIDUpgrade[x].
Upgrade EDID data via the RS232 port.
[x] is the input port, when the value of X
is 9, it means upgrade all input ports.
When the switcher receives the
command, it will show a message to
prompt you to send the EDID file (.bin
file). Operations will be canceled after
10 seconds. Please disconnect all
connections for HDBaseT ports.
Please send the
EDID file
EDID/[x]/[y].
Set the EDID data of input port [x] to
built-in EDID No.[y].
[y]=1~5, correspond to the 5 embedded
EDID data separately
EDID/[x]/[y]
UpgradeIntEDID[x].
Upgrade one of the 5 embedded EDID
datas, x is the serial number for EDID
data:
1. 1080P 2D 2CH
2. 1080P 3D 2CH
3. 1080P 2D Multichannel
4. 1080P 3D Multichannel
5. 3840x2160 2D (30Hz)
When the switcher gets the command,
it will show a message to send EDID
file (.bin file). Operations will be invalid
after 10 seconds.
Please send the
EDID file
GetIntEDID[x].
Return the embedded EDID data
ranked x, [x]=1~5
GetInPortEDID[X].
Return the EDID data of input [x],
[x]=1~4
%0801.
Auto HDCP management, activate
carrier native mode
%0801
%0911.
Reset to factory default.
Factory Default
%9951.
Check the command sent by port 1
when PWON.
Port 1:data when
PWON
%9952.
Check the command sent by port 2
when PWON.
Port 2:data when
PWON
%9953.
Check the command sent by port 3
when PWON.
Port 3:data when
PWON