AVG-CS-HDMI44
RS232 Commands
Communication protocol: RS232 Communication Protocol
Baud rate: 9600 Data bit: 8 Stop bit: 1 Parity bit: none
System Command:
Command
Description
Command Example and
Response
/*Type;
Report system model.
/*Type;
CE-MX44
/%Lock;
Lock front panel buttons.
/%Lock;
System Locked!
/%Unlock;
Unlock front panel buttons.
/%Unlock;
System UnLock!
/^Version;
Report software version.
/^Version;
V1.0.0
Undo.
Cancel the current operation and return to
previous switching status.
Undo.
Undo Ok!
PWON.
Power on the system.
PWON.
PWON
STANDBY.
Turn the system to standby mode.
STANDBY.
STANDBY
%9961.
Report the system locking status.
%9961.
System UnLock!
System Locked!
%9962.
Report the system power status.
%9962.
PWON
%0911.
Reset to factory default.
%0911.
Factory Default
Preset Setting:
Command
Description
Command Example and
Response
Save[y].
Store the current switching status to present
[y]. y=0~ 9.
Save3.
Save To F3
Recall[y].
Recall present [y]. y=0~ 9.
Recall9.
Recall From F9
Clear[y].
Clear the present [y].
Clear9.
Clear F9