![Avery Weigh-Tronix TT-830 Скачать руководство пользователя страница 47](http://html1.mh-extra.com/html/avery-weigh-tronix/tt-830/tt-830_service-manual_3030615047.webp)
47
SSCU-8 Caution!
The Solid State Control Unit 8 (SSCU-8) option
boards require that the total cable length from the
indicator to the last SSCU-8 box/card be two
meters (approx. six feet) maximum. Noise prob-
lems and intermittent communications with the
SSCU-8 card will occur if this guideline is not
followed.
The SSCU-8 card should be isolated from any
other possible grounds (i.e. box, conduit, etc.).
Only the cable connections from the indicator
should provide ground to the SSCU-8 card.