05/09 Rev. 5.02-01
USER MANUAL
Setup & Operation
AP4.4 – AP5.4
20
Possible Errors
Shortly after activating the internal rewinder, the following error message may
be displayed:
Possible causes:
•
No printing material has been inserted, or the material’s end was not fixed
to the rewinder. Attach the end to the rewinder and press the Online button.
•
The printing material is not stretched taut. Press the Online button.
The printer is now ready for the next print job. As soon as the print job is re-
ceived, the rewinder’s control electronics analyse the material width and print
speed as specified by the print job and calculate basic initialisation settings for
the rewinding process. These settings cover most areas of application.
In some challenging applications, a reduced impression accuracy may occur.
In cases like these, the basic initialisation settings can be changed. This may
be necessary in the case of:
•
Very small labels
•
Very rough backing paper
•
Backing paper much heavier than label
•
Labels stuck to backing paper
•
Backing paper perforated along label contour
¯
Basic initialisation settings may only be changed by a qualified authorised
service technician!
Activate/Deactivate Dispenser
¯
Only applies to the model AP 5.4 with internal rewinder and dispensing
edge!
Deactivate
«
Set
SYSTEM PARAMETER > Periph. Device
to
None
Activate
«
Call
SYSTEM PARAMETER > Periph. Device
to
Dispenser
The printer is restarted. The main menu now contains the additional menu
DISPENSER PARA
, which holds the parameters required for dispenser opera-
tion:
For more details on the listed parameters, see topic
Info- Printouts and Para-
meters
, section ”Operating the Parameter Menu”.
Status 5004
Rewinder mat. tear
Parameter
Possible Settings
Dispenser Mode
Real 1:1 mode (default), batch mode, normal 1:1 mode
Dispensing Position
Set in millimeters (default: 0.0 mm)
Display Mode
Job rest quant. (default), Dispense counter
Dispense counter
Preset Amount (default: 0)
Application Mode
Safe Mode (default), Immediate Mode
Start Mode
Edge (default), Level low active
Start Source
Foot switch (default), Light barrier
[Tab. 1] Parameters in the menu DISPENSER PARA.