FXT 5000 Series Field Service Guide
3.2 Attaching a Console to an FXT 5000 Series Node
You will need to attach a console to the node’s serial port in certain situations, including these:
• The Avere Control Panel becomes unresponsive and SSH terminal access to the cluster or individual nodes
fails
• To monitor a node’s boot process after replacing both system drives
The serial port on the FXT 5000 Series node is configured as follows:
• Speed: 115200 baud
• Data bits: 8
• Stop bits: 1
• Parity: None
• Flow control: None
To attach the console:
1. Locate the serial (COM1) port on the rear of the node
2. Use a null modem cable to connect the COM1 serial port to a terminal configured for ANSI-115200-8N1.
3. Log in to the console.
3.3 FXT 5000 Series Front and Rear Illustrations
These diagrams show the front and rear layouts of FXT 5000 Series nodes. Front views are shown without the op-
tional bezel.
The rear layout is the same for all FXT 5000 Series nodes.
3.3.1 FXT 5200 Front Illustration
10