26
PORT A : B
Again, there is probably no need for you to access this menu as it should be used for testing purposes only. You should
rely on the setting chosen in ATM SELECT, but we will provide a brief overview of this menu. Press the “Up” or “Down”
button to move the cursor to “PORT A : B” and press “Set”. The following sub-menu will appear:
PROGRAMMING THE VSSI-PRO
VSSI-Pro VIDEO SERIAL ATM INTERFACE
ASYNC
Press the “Up” or “Down” button to move the cursor to “ASYNC” and press “Set”. The following sub-menu will appear:
Figure 30: ASYNC Sub-Menu
ADDRESS SETUP
ANY
BAUD RATE
2400
PARITY
NONE
DATA BITS
8
EXIT
Figure 29: Port A : B Sub-Menu
ASYNC
BISYNC
SDLC
EXIT
ADDRESS SETUP
Choices: ANY, 1 through 254
Press the “Up” or “Down” button to move the cursor to “ADDRESS SETUP” and press “Set”. The cursor will start
flashing. Press the “Up” or “Down” button to toggle between values and press “Set” when the desired value is dis-
played.
BAUD RATE
Choices: 1200, 2400, 4800, 9600, 14.4K, 19.2K, 28.8K, 38.4K, 57.6K, 115.2K
Press the “Up” or “Down” button to move the cursor to “BAUD RATE” and press “Set”. The cursor will start flashing.
Press the “Up” or “Down” button to cycle through the values and press “Set” when the desired value is displayed.
PARITY
Choices: NONE, EVEN, ODD
Press the “Up” or “Down” button to move the cursor to “PARITY” and press “Set”. The cursor will start flashing. Press
the “Up” or “Down” button to toggle between values and press “Set” when the desired value is displayed.