Pinout for DB25 FEMALE
NOT CONNECTED
HEATER OUT
TEMP POWER IN
INDICATOR 1
INSTANT TRIGGER
TRIGGER IN
INDICATOR 2
INDICATOR 3
INDICATOR 4
12 VDC OUT
SPEED OOMETER IN
GND
NOT CONNECTED
FAN OUT
NOT CONNECTED
GROUND
12 VDC
12 VDC SWITCHED
GROUND
12 VDC SWITCHED
GROUND
12 VDC OUT
GROUND
POWER LED OUT
RECORD LED OUT
Heater Out
Heater Out output become low when the temprature of the RT-195-SW becomes less than 40F.
Temperory Power In
Temperory Power In is an active high input. It can power up the VCR for 5 minutes upon
receving a input pulse.
Indicator 1-4
Indicator 1- 4 can be set as active high or active low inputs. You can label those input in the
programming mode. Factory default setting is Indicator 1 is LT (leftsignal), indicator 2 is BRK
(break), indicator3 is STP (STOP), and indicator 4 is RT(right signal). Upon reciving a active high
input RT-195-SW will display that label on monitor. See section 7.6 for more details.
Trigger IN
It is recommended to connect Trigger In with the car ignition switch. That will turn on the
VCR every time you start your car.