3) Disconnection
To disconnect the system, slide the key in with the control panel fully or partially connected.
The green LED switches off. The AP also supplies important information about the status of the system
with "fault" and "alarm" indications. These indications are summarised and have the purpose of
making the user check the control panel pilot lights to inspect in detail the events that have occurred.
The table below shows the way this information is shown along with its meaning.
MaINs aND BaTTERY
CONNECTIONs
For the control panel opera-
tion, a 12v/6.5Ah backup
battery must be connected
and housed inside the con-
trol panel in its special seat,
as shown in figure 4.
Connect the two 230Vac
mains voltage wires to the
two terminals, as shown in
figure 4
.
CONNECTION TERMINaL
BLOCK (page 32) aND
aPPLICaTION DIaGRaM
(page 1B)
The terminal block is compo-
sed of No. 26 screw termi-
nals with bracket tightening (rating 2.5 mm
2
) of the conductor.
note:
if one of the 7 zones is not used, close the zone by connecting a jumper to the terminal board
between the input of the zone and the GND.
- 26 -
Green L1 LED:
flashing.
This groups one or more of the following:
• flat battery;
• one or more lines open (indication displayed only with the
control panel disconnected);
• o n e o r m o r e l i n e s e x c l u d e d t h o u g h t h e r e l a t i v e z o n e
exclusion pushbuttons located on the control panel (indica-
tion displayed only with the control panel disconnected).
Red L3 LED:
flashing.
Indicates that one or several zones of the system
connected have detected ad alarm with (indication displayed
only with the control panel connected).
Fault
alarm
Fig. 4
Main
board
Wall fixing hole
Battery seat
230 vac connection
terminal block