Fault Diagnosis
Symptom
Possible Cause
Remedy
Page Ref
* Pages 13-15 if a swivel head is used instead of a nose assembly
† Page 15 if a swivel head is used instead of a nose assembly
Item numbers in
bold
refer to the general assembly drawing and parts list on pages 22-23.
More than one
Air leak
Tighten joints or replace components
operation of the
Insufficient air pressure
Adjust air pressure to within specification
5
trigger needed to
Lack of lubrication
Lubricate tool at air inlet point
7
place fastener
Worn or broken jaws
Fit new jaws
8-11*
Low oil level or air in oil
Prime tool
24-25
Build up of dirt inside the nose assembly
Service nose assembly
8†
Tool will not grip
Worn or broken jaws
Fit new jaws
8-11*
stem of fastener
Build up of dirt inside the nose assembly
Service nose assembly
8-11*
Loose jaw housing
Tighten against locking ring
8-11*
Weak or broken spring in nose assembly
Fit new spring
8-11*
Incorrect component in nose assembly
Identify and replace
8-11*
Rotary valve incorrectly adjusted
Read ‘Operating Procedure’
7
Jaws will not release Build up of dirt inside the nose assembly
Service nose assembly
8†
broken stem of
Jaw housing, nose tip or nose casing
fastener
not properly seated
Tighten nose assembly
8
Weak or broken spring in nose assembly
Fit new spring
8-11*
Air or oil leak
Tighten joints or replace components
Low oil level or air present in oil
Prime tool
24-25
Cannot feed next
Broken stems jammed inside tool
Empty stem collector
4 (point 14)
fastener
Check jaw spreader is correct
8-11*
Adjust air pressure to within specification
5
Rotary valve incorrectly adjusted
Adjust as in ‘Operating Procedure’
7
Slow cycle
Lack of lubrication
Lubricate tool at air inlet point
8
Low air pressure
Adjust air pressure to within specification
5
Build up of dirt inside the nose assembly
Service nose assembly
9†
Tool fails to operate
No air pressure
Connect and adjust to within specification
5
Damaged trigger valve
41
Replace
22-23
Loose base cover
35
Tighten
22-23
Loose stem collector
Tighten retaining nut
21
22-23
Fastener fails to break Insufficient air pressure
Adjust air pressure to within specification
5
Fastener outside tool capability
Use more powerful Genesis tool.
Contact Avdel UK Limited
Low oil level or air present in oil
Prime tool
24-25
Other symptoms or failures should be reported to your local Avdel authorised distributor or repair centre.