17
F a u l t D i a g n o s i s
Pneumatic motor
Air leak from motor
Check for worn seals. Replace
13
runs slowly
Low air pressure
Increase
7
Air way blockage
Clear restriction in air supply
Worn drive screw
Replace
8
Vanes jamming
Lubricate tool through air inlet
Insert does not
Stroke incorrectly set
Adjust
7
deform properly
Air pressure outside the tolerance
Adjust
7
Low oil level
Prime tool
16
Insert out of grip
Check grip range of Insert
Drivescrew turns
Worn or damaged drive shaft
Replace
independent of
Worn or damaged drive screw
Replace
8
motor
Adaptor nut loose
Tighten
8
Locking ring
90
missing
Fit new locking ring
13
Insert will not
Incorrect Insert thread size
Change to correct insert
place onto
Incorrect drive screw fitted
Change to correct drive screw
drivescrew
Worn or damaged drive screw
Replace
Nose equipment incorrectly assembled
Disconnect air supply, re-fit nose
8-9
equipment carefully
Tool is jammed
Excessive stroke/
DO NOT DEPRESS TRIGGER. Unlock
on placed insert
Defective insert/
stroke locking device and bring
Worn or defective drive screw
rear casing forward to zero stroke
position. Depress trigger. Tool
should spin off. Reset stroke. If not,
disconnect air to tool. Insert a
4 mm Ø pin through nose casing slots
into spindle
44
. Turn until drive screw
leaves. Insert. Use new insert AND
drive screw.
Drive screw
Stroke of tool excessive
Re-set stroke
breaks
Side load on drive screw
Hold tool square to application when
placing Insert
continued overleaf
Item numbers in
bold
refer to general assembly drawings and parts list (pages 14-15).
Other symptoms or failures should be reported to your local Avdel authorised distributor or repair centre.
S y m p t o m
P o s s i b l e C a u s e
R e m e d y
P a g e R e f
Содержание 74200
Страница 18: ......
Страница 21: ...Instruction Manual Original Instruction Threaded Insert Power Tool 74200...