background image

Installing the Avaya Virtual Services
Platform 7200 Series

Release 6.0

NN47228-302

Issue 04.01

November 2016

Содержание Virtual Services Platform 7200 Series

Страница 1: ...Installing the Avaya Virtual Services Platform 7200 Series Release 6 0 NN47228 302 Issue 04 01 November 2016 ...

Страница 2: ...Y TO BIND SUCH ENTITY TO THESE TERMS OF USE IF YOU DO NOT HAVE SUCH AUTHORITY OR IF YOU DO NOT WISH TO ACCEPT THESE TERMS OF USE YOU MUST NOT ACCESS OR USE THE HOSTED SERVICE OR AUTHORIZE ANYONE TO ACCESS OR USE THE HOSTED SERVICE Licenses THE SOFTWARE LICENSE TERMS AVAILABLE ON THE AVAYA WEBSITE HTTPS SUPPORT AVAYA COM LICENSEINFO UNDER THE LINK AVAYA SOFTWARE LICENSE TERMS Avaya Products OR SUCH...

Страница 3: ...ECT TO CODECS IF THE AVAYA CHANNEL PARTNER IS HOSTING ANY PRODUCTS THAT USE OR EMBED THE G 729 CODEC H 264 CODEC OR H 265 CODEC THE AVAYA CHANNEL PARTNER ACKNOWLEDGES AND AGREES THE AVAYA CHANNEL PARTNER IS RESPONSIBLE FOR ANY AND ALL RELATED FEES AND OR ROYALTIES THE G 729 CODEC IS LICENSED BY SIPRO LAB TELECOM INC SEE WWW SIPRO COM CONTACT HTML THE H 264 AVC CODEC IS LICENSED UNDER THE AVC PATEN...

Страница 4: ...32 LED state definitions 35 Switch LEDs 35 100 Mbps 1 Gbps 10 Gbps RJ 45 port LED state indicators 36 SFP and SFP port LED state indicators 37 QSFP port LED state indicators 37 Management port LED state indicators 38 Enterprise Device Manager EDM representation of physical LED status 38 Installing the switch in an equipment rack 39 Using the optional slide rack mount kit 39 Using the supplied brac...

Страница 5: ...ing Avaya Mentor videos 79 Searching a documentation collection 80 Subscribing to e notifications 81 Contents November 2016 Installing the Avaya VSP 7200 Series 5 Comments on this document infodev avaya com ...

Страница 6: ...se This guide provides information and instructions to install an Avaya Virtual Services Platform 7200 Series VSP 7200 Series switch November 2016 Installing the Avaya VSP 7200 Series 6 Comments on this document infodev avaya com ...

Страница 7: ...2 Release 6 0 Resources Information about related resources is moved to the last chapter in this document USB Port version The USB port version is mentioned as USB 2 0 port and the instances of USB slot are replaced with USB port wherever applicable November 2016 Installing the Avaya VSP 7200 Series 7 Comments on this document infodev avaya com ...

Страница 8: ...les and one front to back 460 W AC PSU 48 1 10 GbE SFP SFP ports six 40 GbE QSFP ports one 10 100 1000 BASE T Out Of Band Management Port one RJ 45 Console Port one USB 2 0 port Base Software License three field replaceable fan modules EC7200x1B E6 and EC7200x1F E6 Note Replace the x with a country specific power cord code See the footnote for details VSP 7254XSQ Port Licensed fiber switch Include...

Страница 9: ...Replace the x with a country specific power cord code See the footnote for details VSP 7200 DC models VSP 7254XSQ fiber switch Model EC720001F E6 ships with one front to back 800 W DC PSU 48 1 10 GbE SFP SFP ports six 40 GbE QSFP ports one 10 100 1000 BASE T Out Of Band Management Port one RJ 45 Console Port one USB 2 0 port Base Software License three field replaceable fan modules EC720001F E6 VS...

Страница 10: ... watt DC redundant power supply The VSP 7254XSQ and VSP 7254XTQ comes with one 800 W DC PSU For full power redundancy you can install a second 800 W DC PSU EC8005001 E6 front to back Note Avaya does not support a back to front DC power supply Note The character x in the order number indicates the power cord code Replace the x with the proper letter to indicate desired product nationalization See t...

Страница 11: ...tion and testing Avaya will not be responsible for issues related to non Avaya branded transceivers The VSP 7200 Series operates in forgiving mode for SFP transceivers which means that the switch will bring up the port operationally when using non Avaya SFP transceivers Avaya does not provide support for operational issues related to these SFPs but they will operate and the port link will come up ...

Страница 12: ...7254XSQ 40 Gbps ports whether channelization is enabled or not Port licensing support On the port licensed VSP 7254XSQ fiber switch 24 ports Slot 1 ports 25 to 48 out of the 48 1 10 GbE SFP SFP ports require a Port License to be unlocked two ports Slot 2 ports 5 and 6 out of the six 40 GbE QSFP ports require a Port License to be unlocked On the port licensed VSP 7254XTQ copper switch 24 ports Slot...

Страница 13: ... seen if both ends are set to 100 Mbps auto negotiation disabled and you use a straight through cable If Link instability is seen when you use a cross over cable a port disable or enable can fix the issue For more information see Installing Transceivers and Optical Components on VSP Operating System Software NN47227 301 Hardware models for VSP 7200 Series November 2016 Installing the Avaya VSP 720...

Страница 14: ...ant PSU to provide redundancy and load sharing See AC power supply specification on page 24 or DC power supply specifications on page 31 To order redundant PSUs see Hardware models for VSP 7200 Series on page 8 for part numbers 3 Verify that the fan module air flow is going in the same direction as the power supplies either front to back or back to front Optionally order redundant fan modules To o...

Страница 15: ...rmination 8 Prepare the rack Ensure that there is enough rack space to accommodate a 1RU switch 4 45 cm Ensure that the rack is bolted to the floor and braced if necessary Ensure that the rack is grounded to the same grounding electrode used by the power service in the area The ground path must be permanent and must not exceed 1 Ohm of resistance from the rack to the grounding electrode Preinstall...

Страница 16: ...n an equipment rack Using the optional slide rack mount kit on page 39 Using the supplied bracket on page 70 2 Install the primary or redundant power supply Important Avaya does not support a combination of AC input and DC input power supplies in the same chassis If you have an AC power supply see Installing an AC power supply on page 22 If you have a DC power supply see Installing a DC power supp...

Страница 17: ...dicates the top port the down arrow on the right indicates the bottom port For a description of what the LEDs mean see RJ 45 copper port LEDs on page 36 or SFP port LEDs on page 37 2 48 ports The VSP 7254XSQ has 48 SFP SFP fiber ports The VSP 7254XTQ has 48 RJ 45 copper ports 3 Six QSFP ports The LEDs are below each port There are four LEDs per port to support channelization The up arrows refer to...

Страница 18: ... result in complete or intermittent failures While networking equipment is commonly designed and tested to withstand common mode ESD events voltage can sometimes discharge to some connector pins which can potentially damage the networking equipment Caution To protect the switch against ESD damage take the following measures before you connect data cables to the device Always use antistatic wrist s...

Страница 19: ... discharge cable perform this procedure 1 Connect the ground lug on the ESD discharge cable to a safe and suitable earth ground 2 Connect all RJ 45 cable connectors to the female RJ 45 connector of the ESD discharge cable for at least 5 seconds and then connect each RJ 45 cable connector to the switch 3 Leave cables connected to the networking equipment After you connect cables to networking equip...

Страница 20: ...26 hours 30 5 years Table 3 Environmental specifications Operating Temperature 0 C to 50 C 32 F to 122 F Storage Temperature 40 C to 85 C 40 F to 185 F Operating Humidity 0 to 95 percent noncondensing Storage Humidity 0 to 95 percent noncondensing Maximum Operating Altitude 3 048m 10 000 feet above sea level Storage Altitude 0 to 12 192m 0 to 40 000ft above sea level Acoustic Noise VSP 7254XSQ F2B...

Страница 21: ...s with the unit 4 Power cord The VSP 7200 A models EC7200A1B E EC7200A1F E6 EC7200A2B E6 and EC7200A2F E6 do not include a power cord for the AC power supply All other models include a country specific power cord The VSP 7200 DC models EC720001F E6 and EC720002F E6 ships with a DC power supply wiring assembly for the DC power supply 5 Three field replaceable fan modules either front to back or bac...

Страница 22: ...7205B1F E6 460W AC POWER SUPPLY FRONT2BACK COOLING EU PC EC7205C1B E6 460W AC POWER SUPPLY BACK2FRONT COOLING UK PC EC7205C1F E6 460W AC POWER SUPPLY FRONT2BACK COOLING UK PC EC7205D1B E6 460W AC POWER SUPPLY BACK2FRONT COOLING JP PC EC7205D1F E6 460W AC POWER SUPPLY FRONT2BACK COOLING JP PC EC7205E1B E6 460W AC POWER SUPPLY BACK2FRONT COOLING NA PC EC7205E1F E6 460W AC POWER SUPPLY FRONT2BACK COO...

Страница 23: ...Note The design of the latch mechanism that secures the power supply enforces this safety practice Procedure 1 If there is a power supply cover remove it and save for possible future use To remove the cover push the tab on the spring latch to the left and pull on the extraction handle Important If you only have one power supply installed the other slot must be covered to ensure proper ventilation ...

Страница 24: ... power to the VSP 7200 Series Allow at least 30 seconds for the VSP 7200 Series to fully power down before restoring power Otherwise the VSP 7200 Series might produce a core file during the reset leading to an extra delay during boot time Always connect the AC power cord in a location that is quickly and safely accessible in case of an emergency 5 Check the LED on the bottom right side of the powe...

Страница 25: ...e that regulatory power specifications are based on the maximum rated capacity of the power supplies and are not based on typical power consumption which is typically lower Table 4 460 W AC power specifications 7254XSQ Input Current 460 W 90 or 460 180 88 5 8 A maximum at low input voltage 2 9 A maximum at high input voltage Input Voltage rms 100 127 V or 200 240 V 47 63 Hz 50 60 Hz nominal Power ...

Страница 26: ...lug specifications Table 6 International power cord specifications Country and Plug Specification Specifications Typical Plug Continental Europe CEE7 standard VII male plug Harmonized cord HAR marking on the outside of the cord jacket to comply with the CENELEC Harmonized Document HD 21 220 or 230VAC 50 Hz Single phase United States of America Canada and Japan NEMA5 15P male plug UL recognized UL ...

Страница 27: ... supply to provide redundancy and load sharing Both the VSP 7254XSQ fiber switch and the VSP 7254XTQ copper switch use the same DC power supply model EC8005001 E6 front to back cooling There are two power supply slots PSU1 on the left side and PSU2 on the right If you only have one power supply you can install it in either PSU1 or PSU2 If you install a second power supply neither one acts as a pri...

Страница 28: ...If a power supply fails replace it as soon as you can but leave it in place until you do Leaving a power supply slot unpopulated impairs the ability of the fans to cool the chassis 2 Slide the power supply into the slot 3 Verify that the power supply is fully seated in the slot The spring latch should engage and return to its original position Installing the Avaya Virtual Services Platform 7200 Se...

Страница 29: ...wer down before restoring power Otherwise the VSP 7200 Series might produce a core file during the reset leading to an extra delay during boot time 4 Once you install a power supply use the following steps to connect the DC power supply wiring assembly a Avaya supplies a DC power supply wiring assembly to connect the DC power supply to the DC input power source b Refer to the tag attached to the D...

Страница 30: ...reen blinking The power supply is present but its output is standby voltage 12VSB Amber steady SHUTDOWN The power supply is not supplying power to the switch because the power cord is unplugged or the power supply shutdown for faults such as a fan failure or exceeding limits for Over Current Protection OCP or Over Voltage Protection OVP Amber blinking WARNING The power supply continues to operate ...

Страница 31: ...fications are based on the maximum rated capacity of the power supplies and are not based on typical power consumption which is typically lower Table 8 DC power specifications VSP 7254XSQ or 7254XTQ Input Current 24 16 A Input Voltage rms 40 5 to 60 VDC Power Consumption 800 W maximum Temperature Operating range 0 to 50 ºC Non operating range 40 to 70 ºC Inrush Current 50 A maximum Turn on Conditi...

Страница 32: ...h Both the VSP 7254XSQ fiber switch and the VSP 7254XTQ copper switch use the same fan module models EC7200BTF E6 12 V BACK2FRONT SPARE FAN MODULES INC 3 FAN MODULE KITS EC7200FTB E6 12 V FRONT2BACK SPARE FAN MODULES INC 3 FAN MODULE KITS There are sensors inside the chassis that monitor the temperature These sensors send information to a controller that automatically regulates the fan speed to ma...

Страница 33: ...5 60 Use this procedure if a fan fails and you have to replace it Important All three fan modules must be installed at all times to ensure proper ventilation If a fan fails replace it as soon as you can but leave it in place until you do Leaving a fan bay unpopulated impairs the ability of the remaining fans to cool the chassis Procedure 1 Check the Fan LED on the front of the chassis Solid green ...

Страница 34: ...les in the VSP 7200 Series and each fan module has two fans for a total of six fans Each fan has its own ID and the show sys info fan command reports its status The Fan IDs are assigned from left to right as you face the back of the chassis For the first fan module on the far left the Fan IDs are 1 and 2 the next fan module has Fan IDs 3 and 4 and the fan module on the far right has Fan IDs 5 and ...

Страница 35: ...r optic equipment can emit laser or infrared light that can injure your eyes Never look into an optical fiber or connector port Always assume that fiber optic cables are connected to a light source Switch LEDs The following table describes the main switch LED state indications provided by LED color and fluctuation cues Important In addition to the fan modules each power supply also has a fan The p...

Страница 36: ...dundant power supply RPS Fan Amber steady A fan module has been removed Amber blinking A fan module has failed Green steady All fan modules are operating normally 100 Mbps 1 Gbps 10 Gbps RJ 45 port LED state indicators This section describes the RJ 45 copper port LED state indicators by color and fluctuation cues The up arrow on the left indicates the top port the down arrow on the right indicates...

Страница 37: ...Mbps if SFP 100 Mbps if SFP Green steady Operating at mid speed 100 Mbps if SFP 1 Gbps if SFP Green blinking Operating at high speed 1 Gbps if SFP 10 Gbps if SFP QSFP port LED state indicators This section describes the transceiver port LED state indicators by color and fluctuation cues The Link Act indicates whether or not the link is established and if a transceiver is present and active Each 40...

Страница 38: ...e port is operating at the low speed Amber steady The port is operating at mid speed Green steady The port is operating at high speed Link Act Off The port has no data activity Amber steady The port has a fault Amber blinking The port is enabled but it has not established a link Green steady The port has established a link but there is no data activity Green blinking The port has established a lin...

Страница 39: ...ice in a rack do not stack units directly on top of one another You must secure each unit to the rack with the appropriate mounting brackets Mounting brackets cannot support multiple units For a translation of this statement see Translations of safety messages on page 75 Using the optional slide rack mount kit The Universal Slide Rack Mount Kit is adjustable so that you can install your switch in ...

Страница 40: ...he slide components and their features The shipping carton contains the following components Two 300mm 600mm slides default configuration Two extension brackets for the 600mm 900mm configuration Two long rear brackets for the 600mm 900mm configuration Bag of screws Figure 6 Shipping components Installing the Avaya Virtual Services Platform 7200 Series November 2016 Installing the Avaya VSP 7200 Se...

Страница 41: ...s to the equipment rack Chassis rail This rail is embedded in the rack rail Later the installation instructions explain how to detach these two rails and install the chassis rail onto your switch Figure 7 Rails Brackets There are three different brackets Short rear bracket The slide rail kit comes with this bracket installed for the 300mm 600mm default configuration Installing the switch in an equ...

Страница 42: ...m configuration The following figure shows the extension bracket and the long rear bracket Both are used for a 600mm 900mm configuration Figure 9 Extension and long rear brackets Locks and latches This section describes the locks and latches on the rails and where they are located Installing the Avaya Virtual Services Platform 7200 Series November 2016 Installing the Avaya VSP 7200 Series 42 Comme...

Страница 43: ...umbscrew lock and release latches Thumbscrew lock This feature is on the front end of the chassis rails and is used to lock the switch in the home position of the equipment rack Installing the switch in an equipment rack November 2016 Installing the Avaya VSP 7200 Series 43 Comments on this document infodev avaya com ...

Страница 44: ...ter you install the switch in a rack you can use the white release latches to remove a switch from an equipment rack if necessary Figure 12 White release latch Blue release latch This latch is a blue plastic tab that is also on the chassis rail Use these latches to slide the switch into the equipment rack Installing the Avaya Virtual Services Platform 7200 Series November 2016 Installing the Avaya...

Страница 45: ...de back into the main part of the unit When you install the switch in a rack and then pull the switch out this mechanism automatically locks the slide rail in a fully extended position Retaining latch These latches are on the front and back of the slide rails Use the hooks on these latches to wrap around the frame of the equipment rack and lock the rail into place Installing the switch in an equip...

Страница 46: ...quare holes the pin block fits right into the holes in the rack For racks with large round holes the pin block retracts halfway when you insert the rail into the rack Installing the Avaya Virtual Services Platform 7200 Series November 2016 Installing the Avaya VSP 7200 Series 46 Comments on this document infodev avaya com ...

Страница 47: ...ck Mount Kit is fairly complex due to its versatile design To make your installation easier read the Inventory of slide components on page 40 section to familiarize yourself with the slide components and features Procedure 1 Disconnect the power cord from the switch 2 Open the shipping carton and remove the bag of screws and the two slides used in 300mm 600mm racks Installing the switch in an equi...

Страница 48: ...ssis in a 600mm 900mm Save them for potential future use 3 Use the following steps to detach the chassis rail from the slide s rack rail a Loosen the thumbscrew lock on the front of the rail Installing the Avaya Virtual Services Platform 7200 Series November 2016 Installing the Avaya VSP 7200 Series 48 Comments on this document infodev avaya com ...

Страница 49: ...Pull the inner chassis rail and slide it out as far as you can Installing the switch in an equipment rack November 2016 Installing the Avaya VSP 7200 Series 49 Comments on this document infodev avaya com ...

Страница 50: ... chassis rail out of the rack rail 4 Lift the blue locking mechanism on the rack rail to slide the outer section back into the main section Installing the Avaya Virtual Services Platform 7200 Series November 2016 Installing the Avaya VSP 7200 Series 50 Comments on this document infodev avaya com ...

Страница 51: ... the front and position the rail over the standoffs on the chassis b Slide the chassis rail to the rear until the rail locks into the standoffs c Make sure the safety tab locks into place Installing the switch in an equipment rack November 2016 Installing the Avaya VSP 7200 Series 51 Comments on this document infodev avaya com ...

Страница 52: ...ust the length of the rack rail so it fits the rack depth by loosening the two screws on the rack rail and adjusting the length Make sure the screws are tight before you install the slides in the rack Installing the Avaya Virtual Services Platform 7200 Series November 2016 Installing the Avaya VSP 7200 Series 52 Comments on this document infodev avaya com ...

Страница 53: ...erent rack types In the default position the pin block fits into racks with square holes When retracted halfway it fits into racks with large round holes When fully retracted it fits into racks with small round holes Installing the switch in an equipment rack November 2016 Installing the Avaya VSP 7200 Series 53 Comments on this document infodev avaya com ...

Страница 54: ...ail on the other side of the frame 7 Use the following steps to install the switch in the equipment rack to complete the installation a Insert the chassis rails on the switch into the rack rails on the frame Installing the Avaya Virtual Services Platform 7200 Series November 2016 Installing the Avaya VSP 7200 Series 54 Comments on this document infodev avaya com ...

Страница 55: ...he lock shown above engages To slide the switch back into the rack push the blue release latches on the chassis rails towards the back and slide the switch into the frame 8 Connect power and network connections to the switch Installing the switch in an equipment rack November 2016 Installing the Avaya VSP 7200 Series 55 Comments on this document infodev avaya com ...

Страница 56: ...rself with the slide components and features Procedure 1 Disconnect the power cord from the switch 2 Open the shipping carton The 300mm 600mm slides are the default configuration Use the remaining parts in the carton for converting the 300mm 600mm slides to 600mm 900mm slides 3 Use the following steps to detach the chassis rail from the slide s rack rail a Loosen the thumbscrew lock on the front o...

Страница 57: ...Pull the inner chassis rail and slide it out as far as you can Installing the switch in an equipment rack November 2016 Installing the Avaya VSP 7200 Series 57 Comments on this document infodev avaya com ...

Страница 58: ... chassis rail out of the rack rail 4 Lift the blue locking mechanism on the rack rail to slide the outer section back into the main section Installing the Avaya Virtual Services Platform 7200 Series November 2016 Installing the Avaya VSP 7200 Series 58 Comments on this document infodev avaya com ...

Страница 59: ... the front and position the rail over the standoffs on the chassis b Slide the chassis rail to the rear until the rail locks into the standoffs c Make sure the safety tab locks into place Installing the switch in an equipment rack November 2016 Installing the Avaya VSP 7200 Series 59 Comments on this document infodev avaya com ...

Страница 60: ...is bracket is for 300mm 600mm equipment racks only and is not used in this installation Save the bracket for possible future use Installing the Avaya Virtual Services Platform 7200 Series November 2016 Installing the Avaya VSP 7200 Series 60 Comments on this document infodev avaya com ...

Страница 61: ...t and the long rear bracket Use these brackets to extend the rack rail for 600mm 900mm racks Installing the switch in an equipment rack November 2016 Installing the Avaya VSP 7200 Series 61 Comments on this document infodev avaya com ...

Страница 62: ... position of how the components are installed The extension bracket with the flat side down goes on top of the rack rail and then the long rear bracket slides into the extension bracket c Orient the extension bracket over the holes in the rack rail Installing the Avaya Virtual Services Platform 7200 Series November 2016 Installing the Avaya VSP 7200 Series 62 Comments on this document infodev avay...

Страница 63: ...rting the screws from the rack rail side and then into the extension bracket The following figure shows the extension bracket attached to the rack rail Installing the switch in an equipment rack November 2016 Installing the Avaya VSP 7200 Series 63 Comments on this document infodev avaya com ...

Страница 64: ...cket f Lift the blue locking mechanism and slowly slide the rail back into the main assembly This exposes a window over the screw holes so you can install the remaining three Installing the Avaya Virtual Services Platform 7200 Series November 2016 Installing the Avaya VSP 7200 Series 64 Comments on this document infodev avaya com ...

Страница 65: ...d with the black retaining latch is in the front of the rack b Adjust the length of the rack rail so it fits the rack depth by sliding the long rear bracket into the extension bracket Installing the switch in an equipment rack November 2016 Installing the Avaya VSP 7200 Series 65 Comments on this document infodev avaya com ...

Страница 66: ...ck types In the default position the pin block fits into racks with square holes When retracted halfway it fits into racks with large round holes When fully retracted it fits into racks with small round holes Installing the Avaya Virtual Services Platform 7200 Series November 2016 Installing the Avaya VSP 7200 Series 66 Comments on this document infodev avaya com ...

Страница 67: ...e rack rail on the other side of the frame 11 Use the following steps to install the switch in the equipment rack to complete the installation a Insert the chassis rails on the switch into the rack rails on the frame Installing the switch in an equipment rack November 2016 Installing the Avaya VSP 7200 Series 67 Comments on this document infodev avaya com ...

Страница 68: ...he lock shown above engages To slide the switch back into the rack push the blue locks on the chassis rails towards the back and slide the switch into the frame 12 Connect power and network connections to the switch Installing the Avaya Virtual Services Platform 7200 Series November 2016 Installing the Avaya VSP 7200 Series 68 Comments on this document infodev avaya com ...

Страница 69: ...g the switch from an equipment rack Follow these steps if you have to remove the switch from an equipment rack Important This procedure requires two people Procedure 1 Disconnect the power cord from the switch 2 Slide the switch out until the lock engages 3 While the person standing in back of the chassis slides both of the white release locks one on each side of the chassis towards the front the ...

Страница 70: ... secure the chassis and prevent it from sliding off the tray during vibration or when inserting or extracting transceivers Caution Do not mount the chassis in a rack without using a customer supplied tray under the chassis The chassis weight will cause damage to a rack especially in an environment with vibration or in an earthquake prone area Procedure 1 Disconnect the power cord from the switch I...

Страница 71: ...a shelf or tray in the rack 4 Insert and tighten the rack mount screws 5 Verify that the switch is securely fastened to the rack 6 Connect power and network connections to the switch Installing the switch in an equipment rack November 2016 Installing the Avaya VSP 7200 Series 71 Comments on this document infodev avaya com ...

Страница 72: ...val of transceivers The following sections describe how to install and remove transceivers in the Avaya Virtual Services Platform 7200 Series switch In this context the term transceiver refers to Small Form Factor Pluggable SFP SFP and Quad 4 channel SFP QSFP For more information about transceiver use and designation see Installing Transceivers and Optical Components on VSP Operating System Softwa...

Страница 73: ...res and store the transceiver in a safe place until you need it Important Discard transceivers in accordance with the proper laws and regulations Console port pin assignments The following section describes the console pin assignments for the RJ 45 connectors in the Avaya Virtual Services Platform 7200 Series Table 17 Console port pin assignments Connector Pin Number Signal 1 Ready to send RTS opt...

Страница 74: ...etwork issues Also avoid the use of break out cables in non channelized ports because this can result in mismatched link status between link partners which can lead to network issues Software limitations The physical switch hardware creates the following software feature limitation For the VSP 7200 Series MACsec is supported only on the 10 Gbps ports of the VSP 7254XTQ model MACsec is not supporte...

Страница 75: ... pas directement sur un autre Chaque module doit être fixé à sa propre baie à l aide des supports de montage appropriés Ces supports ne sont pas conçus pour résister à plusieurs modules Important Precautión Cuando monte este dispositivo en un bastidor no apile las unidades directamente una encima de otra Cada unidad debe fijarse en el bastidor con las abrazaderas de montaje adecuadas Las abrazader...

Страница 76: ...illez à laisser la plaque métallique sur la baie Si vous la retirez l aération du module ne peut pas s effectuer correctement Important Precaution Si no instala ningún módulo en la ranura asegúrese de mantener la placa de la cubierta de metal en la misma Si la retira impedirá que el aire circule y la unidad se refrigere adecuadamente Important Attenzione Se nello slot non vengono installati moduli...

Страница 77: ...tation En outre vous devez dégager un espace minimal dans la zone de câblage pour pouvoir y accéder facilement en cas d urgence Important Advertencia Para apagar el dispositivo debe desenchufar el cable Conecte siempre el cable de alimentación a una toma segura y de fácil acceso por si se produjera alguna situación de emergencia Important Avviso L unico modo per disattivare questo dispositivo cons...

Страница 78: ...De lo contrario al tocar el interruptor puede recibir una descarga eléctrica Si no hay un circuito de toma de tierra en el enchufe puede producirse un exceso de emisiones Important Pericolo Utilizzare esclusivamente cavi di alimentazione dotati di un percorso per la messa a terra Senza un adeguata messa a terra chiunque tocchi lo switch corre il rischio di ricevere una scossa elettrica L assenza d...

Страница 79: ...See Documentation Reference for a list of documentation for all VOSS products For installation and initial setup information of the Open Networking Adapter ONA refer to the Quick Install Guide that came with your ONA Note The ONA works only with the Avaya Virtual Services Platform 4000 Series Training Ongoing product training is available For more information or to register you can access the Web ...

Страница 80: ...mentation collection On the Avaya Support website you can download the documentation library for a specific product and software release to perform searches across an entire document collection For example you can perform a single simultaneous search across the collection to quickly find all occurrences of a particular feature Use this procedure to perform an index search of your documentation col...

Страница 81: ... notifications for example Product Correction Notices PCN which apply to any product or a specific product You can also subscribe to specific types of documentation for a specific product for example Application Technical Notes for Virtual Services Platform 7000 Procedure 1 In an Internet browser go to https support avaya com 2 Type your username and password and then click Login 3 Under My Inform...

Страница 82: ...oducts 8 Scroll through the list and then select the product name 9 Select a release version 10 Select the check box next to the required documentation types Resources November 2016 Installing the Avaya VSP 7200 Series 82 Comments on this document infodev avaya com ...

Страница 83: ...11 Click Submit Subscribing to e notifications November 2016 Installing the Avaya VSP 7200 Series 83 Comments on this document infodev avaya com ...

Отзывы: