Tools & Experience Required 

Page 13 

Preparing for Installation 

Tools & Experience Required 

The installer is expected to have knowledge of INDeX system programming 

General:

 

–  6.5mm slot head screwdriver 

–  No.1 Phillips screwdriver 

–  Cutter/knife for cable ties 

–  Cable ties - 3mm x 50mm 

–  Drill and masonry drill bits 

–  Tape measure (up to 500mm) 

– Spirit 

level 

–  Digital voltmeter (DVM). 

 

Programming:

 

–  Windows 3.x/95 or NT PC with serial port supporting 19.2K baud minimum.  

 

Additional Parts Required 

The following items are required in addition to those supplied by Avaya 

per DECT Base Station: (DBS)

 

–  1 x Slave jack socket (see country variants on page 16) 

–  Single-twisted pair cable (Type CW1308) from MDF to slave jack socket 

 

Environmental requirements 

The planned locations for all parts of the system must meet the following 

requirements: 
–  Check that the area is a well ventilated area, having a temperature range of 0

°

to +40

°

C and a humidity range of 10% to 90% non-condensing 

–  Check there are no flammable materials in the area 

–  Check there is no possibility of flooding 

–  Check that no other machinery or equipment needs to be moved first 

–  Check that it is not an excessively dusty atmosphere 

–  Check that the area is unlikely to suffer rapid changes in temperature and 

humidity 

–  Check for the proximity of strong magnetic fields, sources of radio frequency and 

other electrical interference 

–  Check there are no corrosive chemicals or gasses 

–  Check there is no excessive vibration or potential of excessive vibration, 

especially on the cabinet mounting surface. 

 

Installation Manual 

Page 13 

INDeX CSLC 

38DHB0002UKCA – Issue 8 (26/03/2002) 

Содержание INDeX CSLC

Страница 1: ...INDeX CSLC Installation Manual 38DHB0002UKCA Issue 8 26 03 2002...

Страница 2: ...uring the Base Stations 16 Base Station Cable Measurement 17 DECT Noise Suppression and Echo Cancellation 17 Registering Handsets 17 Changing CSLC User Numbers 18 Subscribing Handsets 18 Switching Bet...

Страница 3: ...se stations and 64 handsets The CSLC 16 supports up to 16 base stations and 128 handsets Each base station can handle up to 4 simultaneous calls Repeater base stations can be used to extend the range...

Страница 4: ...to a DECT system 10 x 24 channels 2 channels per call During a conversation a handset continuously compares the speech quality obtained in its time slot to that in the same time slot on another carri...

Страница 5: ...ded limit of DBSs in one area is four see page 9 Only software PCS 3 DBSs must be used with CSLC Using standard telephony cable base stations can be placed at up to 2km from the CSLC Base stations uni...

Страница 6: ...attery pack provides both the handset registration number and the software level Handsets are supplied with the battery disconnected Ensure that the battery is connected before use Single Chargers The...

Страница 7: ...you will be attempting to determine two factors to achieve the customers requirements The number of base stations required Their best positioning To fulfil this you need to obtain the following detai...

Страница 8: ...re handed over to the next base station at that stage R R R In the worst case call handover from one base station to another can take up to 10 seconds to complete Thus for handset users moving at norm...

Страница 9: ...problem Screened Rooms Typically found in offices involved with TV video and radio production but also possible in computer centres Base station overlap areas In overlap areas the signal from one base...

Страница 10: ...gnal it can accept audio input via a 3 5mm audio jack input for a manual audio quality check Power Supply Input 9VDC 150mA Subscribe Button Audio Input Power Socket The Survey Base Station is supplied...

Страница 11: ...lay any previously entered System ID appears below SYSTEM X where X 1 to 4 Remove previously subscribed ID by pressing 7 You are returned to SUBSCRIPTION CREATE Press to begin subscription 8 The hands...

Страница 12: ...y one handset can be off hook and receive the audio source at any time 4 Check the boundaries of the Survey Base Stations coverage where Q52 is greater than 52 and RSSI is greater than 64 Mark this ar...

Страница 13: ...ironmental requirements The planned locations for all parts of the system must meet the following requirements Check that the area is a well ventilated area having a temperature range of 0 C to 40 C a...

Страница 14: ...top of the slot to be used Insert the new cassette 3 After insertion of the cassette there will be a delay the length of which is dependant upon the number of base stations before the lamp status sta...

Страница 15: ...re all 32 This allows for system expansion and maintenance with the minimum of cable rewiring Ensure that the cable and wires are clearly labelled at both ends Base Station Wrap Speech Speech Base Sta...

Страница 16: ...e Station line cord into it s socket on the Base Station 5 Slide the Base Station onto the mounting bracket a firm push is required to slide the Base Station lugs over the pins on the wall mounting br...

Страница 17: ...llation to alter the settings Registering Handsets After inserting a CSLC cassette into the cabinet the INDeX performs a number of automatic actions It assigns 64 CSLC8 or 128 CSLC user numbers All mo...

Страница 18: ...to the system To do this subscription must first be allowed on the INDeX The subscription process is performed as follows To enable handset subscription 1 From the Administration menu select Linecard...

Страница 19: ...red press until required AUTO appears and press You only need to do this once at any site but you must log on at each site repeating steps 1 to 5 at each site for each handset 7 Your handset bleeps an...

Страница 20: ...menu select User and enter the directory number of the fixed extension 2 Select Extended functions 3 Select Mobile twin number and enter the directory number of the DECT handset this automatically se...

Страница 21: ...st calls from all handsets With a call connected move through the areas that should be covered by base stations Check that no unexpected black spots exist Ensure that the customer is satisfied with th...

Страница 22: ...rnal Antenna Up to 1Km line of sight The range at which the Repeater can work will typically be between 50 and 150m within a building The use of a directional aerial allows the Repeater to be placed u...

Страница 23: ...erform the following 1 Check the proposed position of the Repeater and ensure that A mains power supply is within 2 metres There is a minimum of 200mm s clearance on all sides of the Repeater 2 Use th...

Страница 24: ...so available from the web site https emea businesspartner avaya com index asp as a self extracting file Windows 3 x 1 Insert the first disk 2 In program Manager select File and then Run 3 Type a setup...

Страница 25: ...d Set Up The CLSC number is shown against Allow Subscription Ensure that the Allow Subscription toggle is set to yes and on completion it must be reset back to no Base to synchronize on The base stati...

Страница 26: ...the handset off hook this gives more accurate and realistic survey figures 4 To return the handset to normal operation press and hold until you hear a short bleep Handset Software Version The handset...

Страница 27: ...uency 4 G GAP 3 H Handset software version 26 Handset subscription 18 Hot Desking 20 Humidity 13 I Installation CCFP Admin 24 Interference 9 L Login 19 M Master sockets 15 Measure cable delay 17 Measu...

Страница 28: ...al property related to this product including trademarks and registered to Lucent Technologies has been transferred or licensed to Avaya This document contains propriety information of Avaya and is no...

Отзывы: