Filt
Filters and QOS Configuration for Ethernet Routing Switch 5500
Technical Configuration Guide
47
January 2013
avaya.com
12.2.1.2 Configure the IP elements
Configure three IP elements for UDP destination ports 80, 69, and 137.
ERS5500 Step 1
– Create the IP elements
ERS5500-24T(config)#
qos ip-element 1 addr-type ipv4 protocol 17 dst-port-min 80 dst-
port-max 80
ERS5500-24T(config)#
qos ip-element 2 addr-type ipv4 protocol 17 dst-port-min 69 dst-
port-max 69
ERS5500-24T(config)#
qos ip-element 3 addr-type ipv4 protocol 17 dst-port-min 137 dst-
port-max 137
Please note that prot ocol 17 = UDP.
12.2.1.3 Configure three Classifiers, one for each of the IP elements configured above
ERS5500 Step 1
– Create the an IP Classifier for each IP element created above
ERS5500-24T(config)#
qos classifier 1 set-id 1 name c1 element-type ip element-id 1
ERS5500-24T(config)#
qos classifier 2 set-id 2 name c2 element-type ip element-id 2
ERS5500-24T(config)#
qos classifier 3 set-id 3 name c3 element-type ip element-id 3
The element -id = the element number you assigned in the previous step above
12.2.1.4 Configure Meters
As mentioned in section 5.2 above, if we do not configure a maximum duration rate, the committed burst
will be automatically set to the maximum value. For all 10/100 Mbps and 1 GigE Ethernet ports, the
maximum committed burst is 524,288 bytes. Hence, it does not matter what value you enter for the max -
burst-rate as long is it is greater than the committed-rate.
ERS5500 Step 1
– Create the QoS meters: “m1” with 10M, “m2” with 5M, and “m3” wi th 1M
ERS5500-24T(config)#
qos meter 1 name m1 committed-rate 10000 max-burst-rate 11000 in-
profile-action 2 out-profile-action 1
ERS5500-24T(config)#
qos meter 2 name m2 committed-rate 5000 max-burst-rate 6000 in-
profile-action 2 out-profile-action 1
ERS5500-24T(config)#
qos meter 3 name m3 committed-rate 1000 max-burst-rate 2000 in-
profile-action 2 out-profile-action 1
12.2.1.5 Configure the Classifier Block
For this example, we will create a classifier block named “b1” with the following
ID 1 with Classifier element 1 and meter 1
ID 2 with classifier element 2 and meter 2
ID 3 with classifier element 3 and meter 3