4 Maintenance
All the inspections / maintenance operations (periodical
or extraordinary) must be logged in the Installation
and maintenance Log Sheet.
All inspections and service tasks made to the hoist and
fall arrest device must be carried out by certified
technicians. The relevant maintenance instructions are
provided to each person during the training.
4.
1
Recommended planning
Avanti recommends the following maintenance planning:
Daily
Annually
Every two years
Every five years or 50 hours
(whatever occurs first)
Fr
Frequency
equency
Performed by
Components
User
Overall / Travel path
Control and safety devices
Fall arrest device
Certified Technician
Overall / Travel path
Control and safety devices
Cabin
Traction hoist
Fall arrest device
Overload limiter
Traction and safety wire ropes
Guiding system
Electrical system
Information signs and documents
Doors and hatches
Cabin control box
Safety switches
Interlock system
Platforms
Certified Technician Fall arrest device
Certified Technician Traction hoist
Every 20 years or 250
hours of operation
(whatever occurs first)
At Avanti Workshop Traction hoist
Fall arrest device
4.
2
Alternative planning
Owners who strictly follow the maintenance program and
the daily inspections, and can document it could decide
with taking over the responsibility as well to provide the
following alternative planning:
Frequency
Performed by
Components
Daily
User
Overall / Travel path
Control and safety devices
Fall arrest device
Annually
Certified Technician
Overall / Travel path
Control and safety devices
Cabin
Traction hoist
Fall arrest device
Overload limiter
Traction and safety wire ropes
Guiding system
Electrical system
Information signs and documents
Doors and hatches
Cabin control box
Safety switches
Interlock system
Platforms
Every ten years or every 125
hours of operation (whatever
occurs first)
Certified Technician
Every 20 years or 250
hours of operation
(whatever occurs first)
At Avanti Workshop Tractionhoist
Fall arrest device
Traction hoist
Fall arrest device
11