NOTICE
Certified technicians must carry out an inspection
before first use following the “Inspection and
maintenance Checklist” Appendix.
NOTICE
The inspection before first use must be recorded for
future reference filling the “Installation and
maintenance Log Sheet” Appendix.
3.
10
Disassembling
Disassemble in reverse order and dispose of in
accordance with local authority regulations.
If the lift is not functional, the operations performed
from the lift will have to be carried out using the
appropriate mechanical or electrical help and taking all
the extra precautions needed in order to perform the job
in a safe manner.
The steps to follow may differ from one installation to
another depending on the circumstances (such as the
overall dismantling tasks – or others- taking place in the
wind farm) and means available (cranes, etc.).
10
3.
7
.
3
Safe zone plates
Adjust the final position of the safe zone plate on each
platform, so that the service lift floor is levelled with the
platform floor when it stops.
3.
8
Information signs and warnings
3.
8
.1
Rescue guide
Place the “Rescue Guide” in a visible place next to the
Rescue pendant control on the bottom platform fence.
3.
9
Inspection before first use
A certified technician must carry out an inspection before
first use following the Annual inspection procedure and
filling in the Inspection and maintenance checklist.
3.
7
.
2 Guard locking
system
The guard locking system blocks the fence door when
the service lift is not on the platform.
The service lift detection switch on the platform unlocks the
electromechanical
locking
door
switch
when
detecting the position of the service lift in the platform.
Place and fix correctly the service lift detection switch on the
platform so that it activates correctly when the position of
the service lift on the platform is appropriate.
The electromechanical locking switch must be properly
adjusted and tightened to the platform fence and fully
functional.
1b
1a
2
1
1c
1d
Figure
8
: Guard locking system
Guard locking system
1
1a
1b
1c
1d
2
Electromechanical locking switch
Manual emergency unlocking (interior of the fence)
Manual emergency unlocking (external of the fence)
Actuator
Opening button (normal use)