background image

User Manual

www.AvantcoEquipment.com 3

General Information

Product Specifications

The models:

177(1)(2)(3)(4)(5) HEATED CABINETS Series,

(1) -  HEAT “HEAT” (Only Heat) or  

“H” (Commonly Used)

(2) - PROOF “P”
(3) -  INSULATE “I”(With Insulate) or  

“U” (No Insulate)

(4) -  PAN WIDTH INCH 

For example 18”

(5) -  PAN QTY - From: 12 to 36 

For example: 36

These cabinets are designed to hold hot food at a constant temperature and/or supply humidity when proofing when 
the application applies. These cabinets are not cooking appliances, and should not be used as such. Safe holding 
temperatures and regular temperature checks are necessary for safe and sanitation food handling.

For example:    177 HEAT   18 36

HEATED CABINETS

ONLY HEAT

NO PROOF

PAN QTY 36 PCS
PAN WIDTH 18"
NO INSULATION

For example:    177 HEAT   18 36 I

HEATED CABINETS

ONLY HEAT

NO PROOF

INSULATED
PAN QTY 36 PCS
PAN WIDTH 18"

For example:     177 H P I 18 36

HEATED CABINETS

HEAT

PROOF

PAN QTY 36 PCS
PAN WIDTH 18"
INSULATED

For example:     177 H P I 18 12

HEATED CABINETS

HEAT

PROOF

PAN QTY 12 PCS
PAN WIDTH 18"
INSULATED

For example:     177 H P U 18 12

HEATED CABINETS

HEAT

PROOF

PAN QTY 12 PCS
PAN WIDTH 18"
NO INSULATION

For example:     177 H P U 18 36

HEATED CABINETS

HEAT

PROOF

PAN QTY 36 PCS
PAN WIDTH 18"
NO INSULATION

Item #

Function

Cabinet Size

Insulation

Voltage

Wattage

Overall Dimensions (W x D x H)

177HPU1812

Holding/Proofing

Half Size

Non-Insulated

120V

1440W

23.1" x 33.2" x 30.6"

177HPI1812

Holding/Proofing

Half Size

Insulated

120V

1440W

23.1" x 33.4" x 31.6"

177HEAT1836

Heating Only

Full Size

Non-Insulated

120V

1440W

23.1" x 33.2" x 66.5"

177HEAT1836I

Heating only

Full Size

Insulated

120V

1440W

23.1" x 33.4" x 67.5"

177HPU1836

Holding/Proofing

Full Size

Non-Insulated

120V

1440W

23.1" x 33.2" x 66.5"

177HPI1836

Holding/Proofing

Full Size

Insulated

120V

1440W

23.1" x 33.4" x 67.5"

Содержание 177HEAT1836

Страница 1: ...nual www AvantcoEquipment com 1 Heater Proofer Cabinets Models 177HEAT1836 177HEAT1836I 177HPI1812 177HPI1836 177HPU1812 177HPU1836 Please read and keep these instructions Indoor use only 01 2021 User...

Страница 2: ...nto the module To clean the cabinet wipe with a damp cloth and dry with a towel Use only cleaning agents approved for aluminum CAUTION Water dripping onto the floor from open doors can be a slip hazar...

Страница 3: ...OOF INSULATED PAN QTY 36 PCS PAN WIDTH 18 For example 177 H P I 18 36 HEATED CABINETS HEAT PROOF PAN QTY 36 PCS PAN WIDTH 18 INSULATED For example 177 H P I 18 12 HEATED CABINETS HEAT PROOF PAN QTY 12...

Страница 4: ...xcluding the polycarbonate door panel 5 Using a clean cloth wipe down all surfaces and then let air dry 6 After air drying replace the heated control drawer module by slipping the power cord through t...

Страница 5: ...h the Heat Thermostat will operate continuously when the power switch is turned ON A A B B C C D E Operating Instructions 1 Set HEAT PROOF Switch D to HEAT 2 Set POWER switch A to the ON position Powe...

Страница 6: ...g control knob to desired heat range Allow the unit 45 minutes to pre heat in proofing mode NOTE A use of a hygrometer is recommended for precision proofing applications For proofing trial batches and...

Страница 7: ...175 F Egg Patties Uncovered 180 F French Fries Uncovered 185 F Fried Chicken Uncovered 180 185 F Fried Fish Uncovered 180 F Hamburgers Covered 180 F Lasagna Covered 185 F Mashed Potatoes Covered 175...

Страница 8: ...User Manual 8 www AvantcoEquipment com Drawer Assembly 177DRWRHP Drawer Diagram For Models 177HPU1812 177HPI1812 177HPU1836 177HPI1836...

Страница 9: ...User Manual www AvantcoEquipment com 9 Drawer Assembly 177DRWRHEAT Drawer Diagram For Models 177HEAT1836 177HEAT1836I...

Страница 10: ...14 HCD 035 Knob 2 1 15 HCD 024 Thermometer 1 1 16 HCD 016 Main Switch with Red Light 1 1 177PHCD019 18 HCD 019 Limit Temperature Thermostat 1 1 177PHCD034 19 HCD 034 Temperature Thermostat 2 1 20 HCD...

Страница 11: ...User Manual www AvantcoEquipment com 11 Cabinet Assembly 177HPI1836 Diagram...

Страница 12: ...User Manual 12 www AvantcoEquipment com Cabinet Assembly 177HPU1836 Diagram...

Страница 13: ...User Manual www AvantcoEquipment com 13 B 5 6 2 4 7 3 9 1 13 12 19 10 11 15 18 8 only heat drawer 16 17 14 Cabinet Assembly 177HEAT1836 Diagram...

Страница 14: ...User Manual 14 www AvantcoEquipment com Cabinet Assembly 177HEAT1836I Diagram...

Страница 15: ...User Manual www AvantcoEquipment com 15 Cabinet Assembly 177HPU1812 Diagram...

Страница 16: ...User Manual 16 www AvantcoEquipment com A 23 3 9 13 12 10 24 21 20 22 1 2 4 5 6 7 8 11 18 25 27 26 NONE 19 14 15 16 17 Cabinet Assembly 177HPI1812 Diagram...

Страница 17: ...I1812 08 09 Magnetic Strips Top 1 pc Left Right 2 pcs Included 1 177HPU1836 177HPI1836 177HEAT1836 177HEAT1836I 10 Half Size Door Assembly 1 177HPU1812 177HPI1812 10 Full Size Door Assembly 1 177HPU18...

Страница 18: ...User Manual 18 www AvantcoEquipment com Electric Schematic Power Supply HEAT PROOF Models 177HP Drawer...

Страница 19: ...User Manual www AvantcoEquipment com 19 Only HEAT Models 177HEAT Drawer...

Страница 20: ...cover of drawer Visually inspect to observe for a Loose or disconnected wires b Black or burnt marks on any components c Loose heating elements 4 If any burn marks or discoloration of wires is noted...

Страница 21: ...serial number plate has been removed or altered Damage or failure due to improper installation improper utility connection or supply and issues resulting from improper ventilation or airflow Defects a...

Отзывы: