The temperature range for heating/holding control is 80-185°F. The dial numbers 1-9 do not correspond or relate to a 
specific calibrated temperature. Exact temperature settings must be obtained through familiarization with the unit and 
are dependent on the ambient environment temperature and conditions where the unit is placed. The dial also has an 
OFF position to turn the heater off. Hot holding of food must be done to proper safe food handling and storage prac-
tices. This unit is not a cooker and not meant to cook or rethermalize food. 

The humidity range for humidity/proofing control is 30-100%. The dial numbers 1-9 do no correspond or relate to a 
specific calibrated humidity %. Exact humidity settings must be obtained through familiarization with the unit and are 
dependent on the ambient environment temperature and conditions where the unit is placed. The dial also has an OFF 
position to turn the humidity off. To maintain low temperature range between 85-100°F, switch the proof mode and 
adjust the heat/holding control knob to desired heat range. Allow the unit 45 minutes to pre-heat in proofing mode.
NOTE: A use of a hygrometer is recommended for precision proofing applications. For proofing, trial batches and 
altering control settings is recommended to dial in the unit to the users exact requirements based on the ambient 
temperature and conditions. 

Service Specifications

The Heater-Proofer is an aluminum transport cabinet with heaters to function as a hot food holding cabinet and/or as a 
proofing cabinet.

The heater, or heat drawer, is slid into place on the lower ledges of the cabinet. An electrical power cord is provided 
and plugged into the drawer through an access hole in the back of the cabinet. The main power switch on the front of 
the drawer, when switched ON, will turn on the light in the switch and turn on the air circulating fan in the drawer. The 
circulating fan and 1440W heater element will operate continuously while the unit is ON.

The thermostat control knobs are mounted to the left and right of the HEAT/PROOF switch. The left thermostat knob 
controls the heat in the cabinet from 1 (approx. 30% relative humidity) to 9 (100% relative humidity). Average setting is 6 
(approx. 85% relative humidity).

HEATING/HOLDING INSTRUCTIONS

HUMIDITY/PROOFING CONTROL

Содержание 177HEAT1836

Страница 1: ...nual www AvantcoEquipment com 1 Heater Proofer Cabinets Models 177HEAT1836 177HEAT1836I 177HPI1812 177HPI1836 177HPU1812 177HPU1836 Please read and keep these instructions Indoor use only 01 2021 User...

Страница 2: ...nto the module To clean the cabinet wipe with a damp cloth and dry with a towel Use only cleaning agents approved for aluminum CAUTION Water dripping onto the floor from open doors can be a slip hazar...

Страница 3: ...OOF INSULATED PAN QTY 36 PCS PAN WIDTH 18 For example 177 H P I 18 36 HEATED CABINETS HEAT PROOF PAN QTY 36 PCS PAN WIDTH 18 INSULATED For example 177 H P I 18 12 HEATED CABINETS HEAT PROOF PAN QTY 12...

Страница 4: ...xcluding the polycarbonate door panel 5 Using a clean cloth wipe down all surfaces and then let air dry 6 After air drying replace the heated control drawer module by slipping the power cord through t...

Страница 5: ...h the Heat Thermostat will operate continuously when the power switch is turned ON A A B B C C D E Operating Instructions 1 Set HEAT PROOF Switch D to HEAT 2 Set POWER switch A to the ON position Powe...

Страница 6: ...g control knob to desired heat range Allow the unit 45 minutes to pre heat in proofing mode NOTE A use of a hygrometer is recommended for precision proofing applications For proofing trial batches and...

Страница 7: ...175 F Egg Patties Uncovered 180 F French Fries Uncovered 185 F Fried Chicken Uncovered 180 185 F Fried Fish Uncovered 180 F Hamburgers Covered 180 F Lasagna Covered 185 F Mashed Potatoes Covered 175...

Страница 8: ...User Manual 8 www AvantcoEquipment com Drawer Assembly 177DRWRHP Drawer Diagram For Models 177HPU1812 177HPI1812 177HPU1836 177HPI1836...

Страница 9: ...User Manual www AvantcoEquipment com 9 Drawer Assembly 177DRWRHEAT Drawer Diagram For Models 177HEAT1836 177HEAT1836I...

Страница 10: ...14 HCD 035 Knob 2 1 15 HCD 024 Thermometer 1 1 16 HCD 016 Main Switch with Red Light 1 1 177PHCD019 18 HCD 019 Limit Temperature Thermostat 1 1 177PHCD034 19 HCD 034 Temperature Thermostat 2 1 20 HCD...

Страница 11: ...User Manual www AvantcoEquipment com 11 Cabinet Assembly 177HPI1836 Diagram...

Страница 12: ...User Manual 12 www AvantcoEquipment com Cabinet Assembly 177HPU1836 Diagram...

Страница 13: ...User Manual www AvantcoEquipment com 13 B 5 6 2 4 7 3 9 1 13 12 19 10 11 15 18 8 only heat drawer 16 17 14 Cabinet Assembly 177HEAT1836 Diagram...

Страница 14: ...User Manual 14 www AvantcoEquipment com Cabinet Assembly 177HEAT1836I Diagram...

Страница 15: ...User Manual www AvantcoEquipment com 15 Cabinet Assembly 177HPU1812 Diagram...

Страница 16: ...User Manual 16 www AvantcoEquipment com A 23 3 9 13 12 10 24 21 20 22 1 2 4 5 6 7 8 11 18 25 27 26 NONE 19 14 15 16 17 Cabinet Assembly 177HPI1812 Diagram...

Страница 17: ...I1812 08 09 Magnetic Strips Top 1 pc Left Right 2 pcs Included 1 177HPU1836 177HPI1836 177HEAT1836 177HEAT1836I 10 Half Size Door Assembly 1 177HPU1812 177HPI1812 10 Full Size Door Assembly 1 177HPU18...

Страница 18: ...User Manual 18 www AvantcoEquipment com Electric Schematic Power Supply HEAT PROOF Models 177HP Drawer...

Страница 19: ...User Manual www AvantcoEquipment com 19 Only HEAT Models 177HEAT Drawer...

Страница 20: ...cover of drawer Visually inspect to observe for a Loose or disconnected wires b Black or burnt marks on any components c Loose heating elements 4 If any burn marks or discoloration of wires is noted...

Страница 21: ...serial number plate has been removed or altered Damage or failure due to improper installation improper utility connection or supply and issues resulting from improper ventilation or airflow Defects a...

Отзывы: