background image

User Manual

www.AvantcoEquipment.com 9

Before Use

NOTE: Please use neutral detergent to wash inner pot and lid before use.

Gas Connection

• Connect 0.374 in rubber hose with the external line and fasten tightly.  

(Refer to below picture)

• Use this hose to prevent loss of pressure and difficult ignition. Inspect the hose regularly 

and change immediately if it becomes compromised.

• Do not place the hose underneath the cooker.

Notice

• Failure will occur if the water pan, wind shield, and inner pot are placed improperly. 
• Confirm the following before using for best performance:

 

1. Water pan is placed correctly underneath the bottom. 

 

Improper placement would cause 
unsuccessful ignition or flame-out.

NOTE: Reversed placement of the water pan is not allowed.

 

2. Properly place the wind shield, making sure it is aligned correctly.

Содержание 177GRC110LP

Страница 1: ...o not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance WARNING Improper installation adjustment alteration service or maintenance can cause pro...

Страница 2: ...tions for future reference Index Safety Precautions 3 Specifications 4 Parts List 4 Safe Usage 5 Placement 5 Installation Instructions 6 7 Before Use 8 Notice 8 9 Instructions 9 10 11 Cleaning Method...

Страница 3: ...ot block the steam outlet on the cookers lid or exhaust outlet 4 Use a qualified gas pipeline 5 Please do not use gas pipe made of vinyl or rubber 6 When cooker is not in use make sure gas intake valv...

Страница 4: ...r 0 4MM Model No 177GRC110NAT Power Rating 14 000 BTU Capacity 110 cups 55 cups raw Weight 33 6 lb Dimensions 201 4 D x 171 8 H Orifice Size Drill For Main Burner 1 8MM Orifice Size for Permanent Pilo...

Страница 5: ...NOTE Current national gas types 1 Liquid Propane Gas Y 2 Natural Gas T 3 Manufactured Gas R Placement Keep away from combustible substances Place in area with good ventilation The side and back clear...

Страница 6: ...t Local safety codes should be complied with in respect to fire hazard avoidance 7 Use of the supplied pressure regulator is mandatory Note that the use of 2 regulators may cause insufficient gas flow...

Страница 7: ...GNITE button also engages the WARMING button and exposes it It will stay down until pushed up to extinguish the pilot If the pilot has not lit repeat until the pilot lights 5 If the pilot fails to rem...

Страница 8: ...connector into the gas valve Fig 1 2 Fasten the gas regulator into the rear connector Be sure to follow the direction of the arrow Fig 2 3 3 Double check both the rear connector and the gas regulator...

Страница 9: ...the hose regularly and change immediately if it becomes compromised Do not place the hose underneath the cooker Notice Failure will occur if the water pan wind shield and inner pot are placed improper...

Страница 10: ...urner dry To avoid incomplete combustion do not cover the top of the rice cooker Stay in proximity when the rice cooker is on This is to avoid gas leakage caused by wind blow off Clean the water in th...

Страница 11: ...down COOK BUTTON COOK BUTTON goes up automatically when cooking is finished 6 The cooker keeps warm after COOK BUTTON resumes OFF position 7 Pull WARM BUTTON upwards when warming function is not neede...

Страница 12: ...open the lid after the flame is out Wait about 15 to 20 minutes to avoid possible injury NOTE The recommended time for warming rice is one hour Pull the WARM button upwards when warming is not needed...

Страница 13: ...f the Lid Clean with soap and water Cleaning of Burner Black burner orifice or inset net will cause incomplete combustion In order to have effective combustion clean the burner regularly Please use ne...

Страница 14: ...pan 1 Thermal expansion device replacement 2 Assemble the parts test with the empty pot for 2 3 minutes 1 Use exclusive HVR only 2 Uneven display will cause early switch off watery rice or burned ric...

Страница 15: ...ial number plate has been removed or altered Damage or failure due to improper installation improper utility connection or supply and issues resulting from improper ventilation or airflow Defects and...

Отзывы: