21
400 Series
Operating instructions
Starting the engine
Before starting the engine do the daily checks, see page 27. Adjust the seat and mirrors (if fitted) so that you have a good
working position and unrestricted field of vision from the driver’s seat. Check that all controls function correctly. See
to it that the operating area is safe. Read and follow operating and safety instructions.
Stopping the engine (Safe stopping procedure)
1. Lower the boom completely down. Place attachment firmly on the ground, engage parking brake, stop the attachment
(move auxiliary hydraulics control lever to neutral position, see page 23), set engine revs to idle.
2. Stop the engine by turning the ignition key to the OFF position (to the left)
3. Release auxiliary hydraulics pressure (see page 15).
4. Prevent unauthorized use of the loader. Take off the ignition switch and turn the power off with the battery disconnect switch.
Stop the engine as soon as possible, if any of the following symptoms is observed. Find out the cause before restarting.
• The oil pressure warning light turns on during operation.
• A sudden and unusual noise is heard
• The colour of the exhaust fumes suddenly darkens or turns white.
1. Turn the battery disconnect switch to ON
2. Move the hand throttle lever to approximately ¼ throttle
3. Make sure that auxiliary hydraulics is switched off (lever in neutral
position). Do not press on the drive pedals.
4. Turn the ignition key to the right until the glow plug
indicator light turns on.
5. After the glow plug indicator light turns of turn the ignition
key further to the right until the engine starts.
2
1
2
1
Do not actuate the starter for more than 10 seconds at a time. If the engine does not start, wait for one minute before
repeating attempt. If the engine does not start after a few attempts, or runs poorly, see troubleshooting on page 37 and
the engine owner’s manual.
If auxiliary hydraulics is switched on during starting and there is a hydraulically operated attachment on the
machine, the attachment can move suddenly and cause a dangerous situation. Make sure that the auxiliary
hydraulics control lever is in neutral position during starting.
The engine cannot start if auxiliary hydraulics control lever (no. 7, page 15) is in locking position
Содержание 400 Series
Страница 1: ...English Operator s Manual 2018 420 423 ...
Страница 13: ... 13 400 Series Operating instructions Operating instructions ...
Страница 26: ...26 400 Series Operating instructions ...
Страница 39: ... 39 400 Series EC Declaration of conformity ...