La PETITE-R rev.6 04/2013
· -
INSTALLATION AND SERVICE MANUAL AVALON
La Petite-R
46
www.cafection.com
(800) 561-6162
Cleaning & Sanitizing
8.5.2 Emptying the Waste Bin
Frequency: Daily or every 200 cycles*
After each coffee cycle, the spent grounds and used filter paper are automatically discarded into the
waste bin located in the stand. To prevent the bin from overflowing there is an automatic function which
stops the brewer and shows the following message on the LCD screen:
The maximum setting =
399
The minimum setting =
0
Setting it to 0 will disable the automatic function and will cause an overflow problem if the bin is full.
The equipment will not dispense beverages until the bin is emptied and the counter is reset. To reset
the counter the brewer switch (#SW4) needs to be activated by being turned on and off. This factory set
counter can be adjusted to the waste bin size used. See the machine parameters for more instructions
on changing the setting.
How to empty the stand waste bin:
1. Open the stand door located directly below the brewer;
2.
Cut the filter paper 4“ below the drum with scissors or tear gently; DO NOT YANK ON THE
PAPER!
3. Remove the filled plastic bag from the spent grounds bin and replace with a new one;
4. Activate the brewer switch (#SW4) by turning it on and off (right then left).
How to empty the brewer internal waste bin*:
1. Open the brewer door;
2. Take the front panel off;
3. Activate the brewer switch (#SW4) by turning it ON (to the right);
4. Cut the filter paper 4” below the drum with scissors or tear gently; DO NOT YANK ON PAPER!
5. Activate the brewer switch (#SW4) by turning it OFF (to the left);
6. Replace the front panel and close the door.
It is very important not to yank on the filter paper. Doing so may prevent the brewer from functioning
properly.
* If you are using the internal waste bin provided with the unit, we recommend to set the counter to 25
cycles.
Needs Service
Activate Brewer