2.
Outdoor unit:
No. Part
Operation
Process
Remark
1
General
operation
1) Screw off one fastening bolt from
the electrical box cover, and offload
the box cover;
2) Pull out the interconnection cord
from the electrical box;
3) Screw off the five fastening bolts
from the cover board, and offload the
board;
Screw the six fastening bolts from the
front panel, and offload the front
panel;
4) Screw off the fastening bolts from
the electrical assembly;
5) Screw off the eight fastening bolts
and offload the outer frame;
2
Outdoor fan
motor
1) Do No. “1” firstly;
2) Screw off the fastenings screws
clockwise.
3) Offload the fan.
4) Screw off the four fastening bolts
and offload the fan motor;
5) Screw off the two fastening bolts
and offload the fan motor bracket.