34
output negative ion; In case that Negative ion function is started, press the Negative ion
function button on the remote control, negative ion electrical apparatus on the controller
close, he whole machine will not output negative ion
14. “I Feel” Function
1
、
Enter method
press”I Feel” function button on the remote control, when controller receives signal, then
enter”I Feel” function, at this time, controller will treat the temperature for sensor on the
remote control as Tr on the original controller to deal (including the time of intelligent
defrost) temperature compensation is still effective, frequency will still be counted as
according formula.
2
、
Remote control towards the receiving window for controller, remote control will lunches a
signal every 3min after”I Feel” function starts up.
3
、
When”I Feel” function is starting up, main control board will not check the original Tr
sensor on controller.
4
、
Quitting methods
a)press”I Feel” function button one more tine, this function will be cancelled.
b)If controller can not receive the signal for remote control wthin 10min , “I Feel” function will
be cancelled automatically, Tr will re-control as the temperature that Tr sensor on controller
checks
15. Testing under Rated Work
1
、
Refrigerating rated testing
high wind and temperature 18 C are set , receive signal for sleeping button 8 times
continuously within 8s, if refrigerating rated testing function is set successfully, buzzer will
sound four times, system enter rated testing status, compressor will run as fixed frequency
54Hz, if any one condition above does not work, rated frequency running will quit.
2
、
Heating rated testing
high wind and temperature 30 C are set , receive signal for sleeping button 8 times
continuously within 8s, if refrigerating rated testing function is set successfully, buzzer will
sound four times, system enter rated testing status, compressor will run as fixed frequency
60Hz, if any one condition above does not work, rated frequency running will quit.
16. The Lowest Frequency Testing
1
、
Refrigerating rated testing refrigerating rated testing
high wind and temperature 18 C are set , receive signal for sleeping button 12 times
continuously within 8s, if refrigerating rated testing function is set successfully, buzzer will
sound four times, system enter the lowest frequency testing status, compressor will run as the
lowest frequency 30Hz, if any one condition above does not work, the lowest frequency
testing running will quit.
2
、
Heating rated testing
high wind and temperature 30 C are set , receive signal for sleeping button 12 times
continuously within 8s, if refrigerating rated testing function is set successfully, buzzer will
sound four times, system enter the lowest frequency testing status, compressor will run as the
lowest frequency 30Hz, if any one condition above does not work, the lowest frequency
testing running will quit.
17. High Efficiency Running
High efficiency running only suits for two models: refrigerating and heating.
1
、
Main control board receives high efficiency on remote control and enters high efficiency
Refrigerating: frequency 85Hz, wind speed too high (1130r/min)Heating: frequency
85Hz, wind speed too high (1130r/min), preventing cold wind function is still effective
2
、
time >15min high efficiency stops
3
、
all limiting and protecting terms work during the time of high efficiency
Содержание ASW-H09A4/SAR1DI
Страница 1: ...FOR Split Wall Mounted Series R410a DC Inverter ASW H09A4 SAR1DI ASW H12A4 SAR1DI 2008 ...
Страница 6: ...Remote Controller Instructions 4 ...
Страница 7: ...5 ...
Страница 8: ...6 ...
Страница 9: ...7 ...
Страница 10: ...8 ...
Страница 11: ...9 ...
Страница 12: ...10 ...
Страница 13: ...11 ...
Страница 14: ...12 ...
Страница 15: ...13 ...
Страница 16: ...14 ...
Страница 17: ...15 ...
Страница 42: ...Exploded Pictures 1 Indoor unit exploded picture ASW H09A4 SAR1DI 40 ...
Страница 44: ... 2 Outdoor unit exploded picture ASW H09A4 SAR1DI 42 ...
Страница 46: ... 3 Indoor unit exploded picture ASW H12A4 SAR1DI 44 ...
Страница 48: ... 2 Outdoor unit exploded picture ASW H12A4 SAR1DI 46 ...