Before providing a sample

®

1.

Your Autowatch TAB  reacts very specifically to the presence of alcohol in the breath. 
However,  it  can  be  affected  by,  for  example,  use  of  mouthwash  or  the  application  of  perfume  and 
aftershave  immediately  before  taking  your  sample.  All  of  these  products  contain  alcohol  and  their 
presence may affect the results determined by the instrument.

2.

Similarly, results can also be affected if you have consumed alcohol up to 20 minutes before providing a 
sample. This is because your mouth may still contain residual alcohol from the last drink.

3.

Smoking within up to two minutes of providing a sample may also produce affected results.

TAB  Power-on

The TAB will turn on automatically when a breath sample is required, alternatively to switch on, press and 
release the Power Button. A confirming beep will sound, followed by a series of screens showing:

4.

Windscreen washers and substances that contain Isopropanol can cause the cabin of the vehicle to be 
flooded with vapour. This is breathed in then out when you are taking a breath sample. This will cause 
you to “FAIL” a sample.

5)  Make sure that the temperature of the mouthpiece is not excessively cold. A cold Mouthpiece will cause 

circumvention.

Fit Mouthpiece

Give Sample

IMPORTANT : CORRECT FITTING OF MOUTHPIECE

IMPORTANT : CORRECT FITTING OF MOUTHPIECE

Guide Slot

Mouthpiece 

holder

Guide

While inserting the mouthpiece, ensure Guide Slot lines
up with the guide on the left side of the mouthpiece holder. 

DISPOSABLE MOUTHPIECE

The  mouthpiece  must  be  fitted  into  the 
mouthpiece holder before use of the instrument 
for breath testing.

Please note that the mouthpiece will only fit into 
the instrument if orientated correctly. 

Unwrap mouthpiece from its protective packaging 

and, with the guide slot facing left, slide the mouthpiece into the opening of the mouthpiece holder (with 
instrument display facing you and buttons to the top). 

The guide slot must slide over the corresponding guide pin in the holder and the mouthpiece pushed in until it 
will move no further. 

Failure to correctly insert the mouthpiece may result in the instrument refusing to take a breath sample and 
therefore preventing the vehicle from being started.

The  mouthpieces  are  disposable,  manufactured  under  hygienic  conditions  and  supplied  in  individual 
wrappers. 

 

NB: We recommend that a new mouthpiece is used for each test.

Please recycle mouthpiece fittings

2

Meanwhile, the TAB automatically checks its operating parameters.   When 
the TAB is ready to take a sample a further single beep will sound, followed by 
the message

BREATH TEST PROCEDURE

Autowatch Logo 

Instrument Serial Number & Software Rev.

PFK website

Next scheduled service date

Please Wait

The TAB display will then show 

 with a task bar to show progress of 

sample test.

After a few seconds your breath sample will have been analysed and, if the breath 
alcohol level is below the pre-set limit, then 

"PASS”

 will appear on the TAB display 

and a coded signal will be sent immediately to the VBS in order to unblock the 
Vehicle Blocking System. 

The RED LED will flash rapidly and extinguish confirming that the Blocking System 
has been unblocked. This status will be recorded by the VBS and the TAB with date 
and time.

You may now start your vehicle. (

*The specific time period in which you have to start 

your vehicle is set at a factory default of 5 minutes. This time can be changed by 
arrangement  with  your  service/fitment  centre  and  can  be  set  to  5,  10,  20  or  30 
minutes.)

The TAB will automatically shut down shortly after a valid breath sample is accepted 
or by pressing and holding the large Power button until the TAB shuts down. 

If the ambient temperature is below 25°C the unit will display “Please Wait Unit 
Heating” with a progress bar. The operational temperature of this unit is -40° C to 
85° C

"Analysing"

If the TAB is OFF, switch it ON. When the display shows 

“Fit Mouthpiece, Give 

Sample”

 provide a breath sample as described on page 2.

Before  starting  the  vehicle  the  RED  LED  on  the  Driver  Change  Button  will  be 
flashing indicating that the vehicle is blocked by the VBS (Vehicle Blocking System).

It is recommended that the VBS immobiliser is unblocked 

prior

 to turning on the 

vehicle ignition.

To achieve this, follow the procedure below:

DRIVER 

CHANGE BUTTON

RED 

LED

OPERATING INSTRUCTIONS

26°

16:34

Providing a breath sample

Take a deep breath, seal your lips around the wide end of 
the mouthpiece and blow into it with moderate force. The 
instrument  will  detect  your  breath  flow  and  will  emit  a 
continuous tone as long as you are blowing correctly. Once 
sufficient breath has been blown the tone will stop and a 
click will be heard. The TAB will then analyze your breath 
sample.

NB : It is important to ensure that the breath outlet is not 
blocked in any way while providing a breath sample.

The  user  needs  to  blow  for  at  least  3  seconds.  This 
guarantees deep lung air that has diffused from your blood 
into the air in your lungs, to give a valid alcohol reading.

NOTE : The TAB is equipped with highly sophisticated methods of detecting sample tampering. 
Any attempt to start your vehicle without providing an adult human breath sample will be logged 
within the system and you may be required to explain your actions at a later date.

Keep 

breath outlet 

free of any 

obstructions.

3

Содержание 720 TAB

Страница 1: ...20 540 02 R 3 ISO TS 16949 ISO 14001 CENELEC EN 50436 2 AUTHORISED AUTOWATCH DEALER To order or for more information contact THATCHAM THE MOTOR INSURANCE REPAIRRESEARCHCENTRE USA HOL AUS UK GER SA CDA UK 720 TAB OPERATORS INSTRUCTIONS ...

Страница 2: ...ividual whose blood alcohol content is higher than a pre determined level Ensure that comprehensive instructions and demonstration on the functions and use of this system including blowing techniques is provided by your Service Installation Centre SYSTEM COMPONENTS V E H I C L E B L O C K I N G SYSTEM VBS This unit which contains a buzzer and stores all records is wired into the vehicle s starting...

Страница 3: ...ound followed by the message BREATH TEST PROCEDURE Autowatch Logo Instrument Serial Number Software Rev PFK website Next scheduled service date Please Wait The TAB display will then show with a task bar to show progress of sample test After a few seconds your breath sample will have been analysed and if the breath alcohol level is below the pre set limit then PASS will appear on the TAB display an...

Страница 4: ...limit 2 If the TAB displays Insufficient Sample then one or more of the following could be the cause of the problem Insufficient length of blow Volume Incorrect force of blow Too hard or too soft If Insufficient Sample is displayed after providing a breath sample when the tone was heard it will most likely be an indication of an incorrectly positioned mouthpiece WARM UP TIMES 85 C 10 SECONDS 20 C ...

Страница 5: ...et point of the unit The VBS will then block the vehicle from starting and the vehicle will not start 6 WEEE Directive Do not throw away or dispose of in landfill site Return to local distributor or manufacturer PFK ELECTRONICS PTY LTD 488 Umbilo Road Durban 4001 Kwazulu Natal South Africa Tel 27 31 274 7200 7 Federal Communications Commission FCC Statement 15 21 You are cautioned that changes or ...

Отзывы: