background image

1.

The  TAB  will  turn  “ON”  automatically,  when  the  display  shows  “Fit  Mouthpiece,  Give  Sample” 
follow the same procedure to provide a breath sample as described on page 2.

2.

The TAB analyses the breath sample as before and the VBS records the result.

Should the “Random Testing” option be selected at installation, while the vehicle is on route, the VBS buzzer 
will sound as a request for a random breath sample. (This will be randomly repeated at any stage of the 
journey).

RANDOM “ON THE ROAD” TESTING

Should no breath sample be supplied within a preset period, the buzzer will stop and the RED LED will start to 
flash at a faster rate continuously until a valid sample is presented.

NOTE  :  Failure  to  provide  a  breath  sample  for  analysis  during  random  testing  or  providing  a 
sample that exceeds the predetermined level, will not cause the vehicle to stop, however, failure to 
provide a breath sample or providing a sample that exceeds the predetermined level will cause a 
non event to be presented at the GSM output to be sent if the GSM module is connected (Optional). 
If the vehicle is stopped and the ignition turned off, it will be blocked immediately.

DRIVER CHANGING

Should  a  new  driver  be  required  to  take  over  driving  responsibilities,  the 
following procedure needs to be followed:

1.  As the new driver takes over, the Driver Change Button must be pressed.
2.

The VBS buzzer will sound to request a new breath sample. 

3.

The TAB will turn “ON” automatically, when the display shows “Fit Mouthpiece, Take Sample” follow 
the same procedure to provide a breath sample as described on page 2.

4.

The TAB analyses the breath sample as usual, the VBS records the result and the driver test timer is 
reset.

RED LED

DRIVER CHANGE 

BUTTON

IF THE VBS FAILS TO UN-BLOCK  (Invalid breath sample)

1.

If the TAB displays 

"FAIL”

 then it has detected alcohol in the  breath  at  a  level 

in  excess  of  the  preset  limit.  If  you  have  observed  the  points  shown  in  the 
"Before  Providing  a  Sample"  section  of  these  instructions,  then  you  have  a 
breath alcohol level above the pre-set limit. The RED LED will flash rapidly, and 
the Blocking System will remain blocked, the RED LED will continue flashing 
and the vehicle will not start. This event will be recorded by the VBS with date 
and time. (If the optional GSM module is connected an SMS message will be 
automatically sent to a mobile phone or the control centre that a failure as taken 
place)

The system may also be linked to a fleet management system - ask 

your service/installation centre. 

You  should  wait  for  approximately  30  minutes  and  then  provide  a 
further  sample,  by  which  time  your  body 

may

  have  metabolised  the 

alcohol and reduced the level below the preset limit.

2.

If  the  TAB  displays 

"Insufficient  Sample"

  then  one  or  more  of 

the following could be the cause of the problem.

Insufficient length of blow (Volume).
Incorrect force of blow (Too hard or too soft).
If 

“Insufficient Sample”

 is displayed after providing a breath sample when 

the  tone  was  heard,  it  will  most  likely  be  an  indication  of  an  incorrectly 
positioned mouthpiece.

WARM UP TIMES

  +85°C            10  SECONDS  
   20 °C           < 30 SECONDS

-20°C            < 3 MINUTES

-5°C              < 90 SECONDS

4

Should no breath sample be supplied within a preset time
start to flash at a faster rate continuously until a valid sample is presented.

 period, the buzzer will stop and the RED LED will 

NOTE : Failure to provide a breath sample for analysis during driver changing or providing a 
sample that exceeds the predetermined level will cause the vehicle to remain blocked, moreover, 
will result in a non event being presented at the GSM output to be sent if the GSM module is 
connected  (Optional).    If  the  vehicle  is  stopped  and  the  ignition  turned  off,  it  will  be  blocked 
immediately.

BASIC MAINTENANCE

Cleaning the TAB

If and when required, simply wipe over with a lightly 

dampened cloth.

Calibration and Services

Calibration and Services need to be arranged with 
your Service/ Installation Centre.

NOTE  :  Please  do  not  use  chemical  solvents, 
abrasives or excess water as these could damage 
the  case  material,  and  possibly  the  internal 
sensors.

IMPORTANT : It must be understood by all 
users that the TAB is a highly sophisticated 
and delicate unit.

Downloading Recorded Results

The VBS recorded results can be accessed by 
using the VBS Download software and A cable 
direct to a PC or via RF link with a USB RF dongle. 
This  facility  will  need  to  be  requested  from  your 
Service/Installation Centre.
The  VBS  Download  software  package  can  be 
purchased from your service/Installation centre.

PC 

INTERFACE 

CABLE

RF

DONGLE

or

Connects into the dash 

mounted connector that the

TAB connects into.

Unit displaying “Circumvention” after a breath sample

Remove mouthpiece and warm it with your hand. Retry.

l

If the problem persists please contact you nearest service centre. 

Unit display “Processing Sample” then “Circumvention” or “Suck Back”

l

Turn unit off by holing down the power button for more than 5 seconds.

l

Then turn on the unit wait for it to come ready and display “Fit mouthpiece Give sample”.

l

If the problem persists please contact you nearest service centre. 

No communication between the TAB (handset) and the VBS (vehicle unit).There should be a beep 
from the VBS every time there is communication between the TAB and the VBS.

 

l

Disconnect the TAB cable from the 4-way panel mount connector. 
Re-connect the TAB cable to the 4 way panel mount connector. 

l

The TAB should display “Synchronisation Successful”.

l

If not there could be a problem with TAB, VBS or connection please contact you nearest service 
centre.

l

QUICK TROUBLE SHOOTING GUIDE

5

Содержание 720 TAB

Страница 1: ...20 540 02 R 3 ISO TS 16949 ISO 14001 CENELEC EN 50436 2 AUTHORISED AUTOWATCH DEALER To order or for more information contact THATCHAM THE MOTOR INSURANCE REPAIRRESEARCHCENTRE USA HOL AUS UK GER SA CDA UK 720 TAB OPERATORS INSTRUCTIONS ...

Страница 2: ...ividual whose blood alcohol content is higher than a pre determined level Ensure that comprehensive instructions and demonstration on the functions and use of this system including blowing techniques is provided by your Service Installation Centre SYSTEM COMPONENTS V E H I C L E B L O C K I N G SYSTEM VBS This unit which contains a buzzer and stores all records is wired into the vehicle s starting...

Страница 3: ...ound followed by the message BREATH TEST PROCEDURE Autowatch Logo Instrument Serial Number Software Rev PFK website Next scheduled service date Please Wait The TAB display will then show with a task bar to show progress of sample test After a few seconds your breath sample will have been analysed and if the breath alcohol level is below the pre set limit then PASS will appear on the TAB display an...

Страница 4: ...limit 2 If the TAB displays Insufficient Sample then one or more of the following could be the cause of the problem Insufficient length of blow Volume Incorrect force of blow Too hard or too soft If Insufficient Sample is displayed after providing a breath sample when the tone was heard it will most likely be an indication of an incorrectly positioned mouthpiece WARM UP TIMES 85 C 10 SECONDS 20 C ...

Страница 5: ...et point of the unit The VBS will then block the vehicle from starting and the vehicle will not start 6 WEEE Directive Do not throw away or dispose of in landfill site Return to local distributor or manufacturer PFK ELECTRONICS PTY LTD 488 Umbilo Road Durban 4001 Kwazulu Natal South Africa Tel 27 31 274 7200 7 Federal Communications Commission FCC Statement 15 21 You are cautioned that changes or ...

Отзывы: