background image

 
 
 
 
 
 
 
 
 
 
 
                        FIGURE 24                                                             FIGURE 25 
 

• 

Take the other end of your brine line tube and insert the tube through the small 
hole drilled through the brine tank, and brine well. Loosely unscrew the hex nut 
on the 2310 brine float assembly. Insert the tubing end firmly into the hex nut on 
the 2310 brine float assembly. 

• 

Next back-off the hex nut and ferrule assembly so they are securely onto the 
tubing as shown in Figure 26 below.

 NOTE: Please be sure to assemble the nut 

in the fashion described to prevent system malfunction and possible brine 
tank overflow!

 

• 

Hand-tighten the hex nut snugly onto the 2310 brine float assembly as shown in 
Figure 27 below. 

• 

 

 
 
 
 
 
 
 
 
 
 
 
 
  
                       FIGURE 26                                                               FIGURE 27 
 

• 

Finally, use ½” I.D. tubing to connect the drain bard fitting on the brine tank to a 
floor drain as shown in Figure 28 on the following page. 

NOTE: This is not 

necessary as the 2310 assembly is designed to prevent an overflow situation, , 
but is a good and recommended precaution for a proper installation.

 

 
 
 

© 1999-2007 QualityWaterForLess.com

 

- 9 - 

[email protected] 

Содержание LOGIX 255-760 Meter

Страница 1: ...INSTALLATION START UP INSTRUCTIONS AUTOTROL LOGIX 255 760 METER WATER SOFTENER SYSTEMS 1999 2007 QualityWaterForLess com 1 info qualitywaterforless com ...

Страница 2: ...oncrete on which to place the softener tank and salt tank as known as a brine tank Nearby floor drain or standpipe to connect to the softener for use during each regeneration Un switched power source standard US plug 120v 60hz the softener system includes a 10ft power cord and plug Access to the water main coming into your home You will need to install the softener at this point to assure that wat...

Страница 3: ...nk place a piece of duct tape over the top of the riser to prevent resin from dropping down inside the riser tube as shown in Figure 3 Place the included filling funnel over the top the the tank as shown in Figure 4 and prepare to fill the tank If your softener system came with Gravel please pour this amount into the tank FIRST then pour in the included resin media afterwards FIGURE 3 FIGURE 4 Rem...

Страница 4: ...only NOTE Do not use Teflon tape or pipe dope on the valve or tank threads FIGURE 7 Locate the plumbing adaptors and bypass valve assembly that was shipped with your system as shown in figure 8 on the following page Using the included silicone lubricant packet lubricate the three o rings included and assemble them to the back of the valve as shown in figure 9 on the following page Finally push the...

Страница 5: ...daptor flange as shown in figure 13 below Secure each plumbing adaptor onto the bypass as shown in figure 14 FIGURE 12 FIGURE 13 FIGURE 14 NOTE If using copper connections first prefabricate and sweat a 12 tube section onto each adaptor and cool BEFORE assembly to the bypass This allows you avoid overheating the nut and bypass during future plumbing 1999 2007 QualityWaterForLess com 5 info quality...

Страница 6: ... to run hard water to these fixtures Using soldered copper PVC plastic pipe or flexible connections plumb the system according to all local plumbing codes NOTE If using copper pipe please pre fabricate at least a 12 section of pipe for the IN and OUT bound lines and use a wet rag on the lines being soldered to prevent heat damage during soldering Once all connections have been made place the syste...

Страница 7: ...shown in figure 15 Lubricate and assemble the o ring over the port flange as shown in figure 16 Use Teflon tape on the sight glass air check as shown in figure 17 Assemble the brine fitting onto the sight glass air check as shown in figure 18 being careful not to over tighten Finally use the two included screws to assemble the sight glass air check to the valve as shown in figure 19 FIGURE 15 FIGU...

Страница 8: ...FIGURE 21 Locate the included brine tank and remove the brine tank cover shown in Figure 22 Next locate the brine well and remove the cap as shown in Figure 23 FIGURE 22 FIGURE 23 Pull the 2310 brine float assembly out of the brine well and disassemble the retaining nut as shown in Figure 24 on the following page Next assemble the 2310 brine float assembly to the brine well through the pre drilled...

Страница 9: ... NOTE Please be sure to assemble the nut in the fashion described to prevent system malfunction and possible brine tank overflow Hand tighten the hex nut snugly onto the 2310 brine float assembly as shown in Figure 27 below FIGURE 26 FIGURE 27 Finally use I D tubing to connect the drain bard fitting on the brine tank to a floor drain as shown in Figure 28 on the following page NOTE This is not nec...

Страница 10: ...RE 29 FIGURE 30 Next assemble your I D drain line to the drain barb as shown in Figure 31 on the following page Be sure to use rigid wall I D tubing that will not flatten Wrap electrical tape over the drain tubing to prevent a tubing split and clamp the tubing securely into place with the included blue clamp as shown in Figure 32 on the following page 1999 2007 QualityWaterForLess com 10 info qual...

Страница 11: ...h figures can be treated interchangeably If you get a hardness figure in PPM or mg L please divide this number by 17 1 to get Grains Ex If your hardness is measured at 300 PPM your Grains are 300 17 1 18 Grains Your Iron results should be measured in either PPM or mg L Add your level of iron multiplied by 5 Add this number to your hardness level This final figure will be your Total Hardness Level ...

Страница 12: ... shown in figure 37 below NOTE If this does not show up initially your system has been pre set by us Skip ahead to the next section Use the up arrow to input the number corresponding to your system size Simply divide your system size by 32 000 EX 40 000 32 000 1 25 Press the set button to make this setting active FIGURE 37 1999 2007 QualityWaterForLess com 12 info qualitywaterforless com ...

Страница 13: ...on to make this setting active You will next see the regeneration time on the screen as shown in figure 40 below Press the set button to make the regeneration time begin to flash This setting is used to change the time during the day that the softener will choose to regenerate This setting is usually set to 2 00AM as typically water use is minimal during this time period Use the up or down buttons...

Страница 14: ...r hardness between 10 and 20 grains per gallon and H for hardness aboe 20 grains per gallon Use the up or down buttons to make the appropriate changes to the salt setting Once this has been changed press the set button to make this setting active You will next see the capacity on the screen as shown in figure 43 above DO NOT CHANGE THIS VALUE This number is based on your salt setting chosen above ...

Страница 15: ...your bypass valve to the fully open position NOTE You may see some initial discoloration from the softened water this is normal and should dissipate within the first 40 50 gallons of water used Turn off the nearby faucet when the water runs clear Add approximately five gallons of water to your brine tank and add 120 160 pounds of pellet solar or block salt or potassium chloride to your brine tank ...