regeneration after a set number of days if the meter usage alone does not
automatically initiate it.
(EX every 7
th
day no-matter what)
The “0” means that
the meter will solely regenerate the system and is typical. Press the “set” button to
make the override number begin to flash. Use the “up” or “down” buttons to make
the appropriate changes. Once this has been changed to the desired setting, press
the “set” button to make this setting active.
FIGURE 42 FIGURE 43
•
You will next see the salt setting on the screen as shown in figure 42 above. Press
the “set” button to make the salt setting begin to flash.
The salt setting may be
set to “L” – for hardness under 10 grains per gallon, “S” – for hardness
between 10 and 20 grains per gallon, and “H” – for hardness aboe 20 grains
per gallon.
Use the “up” or “down” buttons to make the appropriate changes to
the salt setting. Once this has been changed, press the “set” button to make this
setting active.
•
You will next see the capacity on the screen as shown in figure 43 above. DO
NOT CHANGE THIS VALUE! This number is based on your salt setting chosen
above, and should not be changed. Press the “down” button to make this setting
active.
•
You will next see the hardness on the screen as shown in figure 44 below. Press
the “set” button to make the hardness number begin to flash. Use the “up” or
“down” buttons to make the appropriate changes to the hardness based on your
water supply. Once this has been changed, press the “set” button to make this
setting active.
FIGURE 44
© 1999-2007 QualityWaterForLess.com