 Function and test method 

 

Item

 

 

Test method

 

 

Criterion

 

 

Standard charge 

CC/CV  mode,  in  the  condition  that  environment  temperature 
is(23±5)

,charging  source  keep  constant  current  charge  with  0.2C 

current until battery voltage reach25.2V,then turn to constant voltage 
charge method until charge current is less than 0.02C(0.062A). 

 

 

Capacity 

 

After standard charge

Shelve battery at indoor temperature for 1h

in  the  condition  that  environment  temperature  is (23±5)

,  constant 

current discharge with 0.2C current until reach the cut-off voltage. 

 

Capacity≥Minimal 

discharge capacity 

 

vibration refer to 

UN38.3 Stands 

 

1. The vibration shall be a sinusoidal waveform with a logarithmic 
sweep between 7 Hz and 200 Hz and back to 7 Hz

 

traversed in 15 

minutes. This cycle shall be repeated 12 times for a total of 3 hours 
for each of three mutually perpendicular mounting positions of the 
cell. One of the directions of vibration must be perpendicular to the 
terminal face. 
2. From 7 Hz a peak acceleration of 1 gn is maintained until 18 Hz is 
reached. The amplitude is then maintained at 0.8 mm (1.6 mm total 
excursion) and the frequency increased until a peak acceleration of 8 
gn occurs (approximately 50 Hz). A peak acceleration of 8 gn is then 
maintained until the frequency is increased to 200 Hz.

 

No leakage,   
No venting,   
No disassembly,   
No rupture and   
No fire, 
voltage≥90% before 
testing 

Overcharge 

protection 

 
Set  the  charge  voltage  of  battery  pack  as  25.2V,  charge  with  0.5C 
current,  experiment  time  less than  24h,  and  stop  charge  when  PCM 
start to protect battery. 

Protection function 
work normally

no 

liquid leakage

no air 

leakage

no fracture

no fire

no explosion 

 

Over discharge 

protection 

Discharge battery pack with 0.8C current

experiment time less than 

24h,and stop discharge when PCM start to protect battery. 

Protection function 
work normally, no 
liquid leakage

no air 

leakage

no fracture

on fire

no explosion 

Short circuit 

protection 

0.5h

After  a  full  charge,short  current  the  discharge  positive  and 

negative  pole  0.5h  with  an  external  circuit  which  resistance  is  no 
more than 50mΩ. 

After  short  circuit  the 
protection  function  is 
normal 

Recycle life 

In the condition that environment temperature is 

23±5

)℃

, standard 

charge, and shelve for 1h, and constant current discharge with 0.2C 
current to the cut-off voltage.   

  500 times discharge 
capacity>70% initial 
capacity of cells 

 

 

 

Содержание AWS-BATTERY

Страница 1: ...SLIDE PTY LTD 7TH JUNE 2022 1 AUTOSLIDE PTY LTD 3 413 VICTORIA STREET WETHERILL PARK 2174 NSW AUSTRALIA Specification for Lithium ion Battery AUTOSLIDE AUTOSWING BATTERY MODEL AWS BATTERY Part Number DY 6S1P18650 2103C ...

Страница 2: ...charge capacity 3 1Ah charge 0 5C 1 55A 25 2V 0 02C 0 62A up to current RT release charge 0 2C 20A 15V end voltage RT Standard voltage 21 6V Discharge protection voltage 2 8V 0 08V Single string voltage protection value Charge voltage 25 2 0 05V Charge mode CC CV Charge protection voltage Level 1 4 2 0 025VLevel2 4 34 2 0 025V Single string voltage protection value with secondary protection Standa...

Страница 3: ...an level 0 5 resistance should be no less than 10KΩ V Accuracy of measuring current instrument should not be less than level 0 5 the relative error of measuring time instrument is 0 1 The current of constant current load is adjustable if it is within the power voltage range the current relative error is 0 1 The current of constant current load is adjustable if it is within the power voltage range ...

Страница 4: ... maintained at 0 8 mm 1 6 mm total excursion and the frequency increased until a peak acceleration of 8 gn occurs approximately 50 Hz A peak acceleration of 8 gn is then maintained until the frequency is increased to 200 Hz No leakage No venting No disassembly No rupture and No fire voltage 90 before testing Overcharge protection Set the charge voltage of battery pack as 25 2V charge with 0 5C cur...

Страница 5: ... cells are used for the work piece process and batteries are delivered from storage 9 Safety specification and instructions Please read the instructions and battery surface marks carefully before use battery Please use battery in the normal and indoor environment In use process stay away from heat source and high voltage prevent children playing with battery Don t throw it Don t short circuit the ...

Страница 6: ...r the fire or under direct sun light It will cause the battery internal protection function loss and abnormal chemical reaction battery may be heating smoking deformation or burn Use dedicated charger and properly charging It is dangerous to charge the battery by non dedicated charger It will cause the battery internal protection function loss and abnormal chemical reaction battery may be heating ...

Страница 7: ...radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encourage...