Test condition
4.1
、
Environmental condition:-
Unless otherwise specified,all test of this specification should be performed under standard
atmospheric condition:
Temperature
:
15
℃~
35
℃
;Relative humidity
:
45%
~
75%;Atmosphere pressure:86kPa
~
106kPa
4.2
、
Measure instrument and equipment requirement
Accuracy of measuring voltage instrument should not be less than level 0.5,resistance should be no less
than 10KΩ/V.
⚫
Accuracy of measuring current instrument should not be less than level 0.5.
⚫
the relative error of measuring time instrument is ±0.1%.
◼
The current of constant current load is adjustable if it is within the power voltage range,the
current relative error is ±0.1%.
◼
The current of constant current load is adjustable if it is within the power voltage range,the
current relative error is ±0.1%.
◼
Charging power (or the charger) should be able to change to constant voltage charging after the
battery voltage achieve constant voltage value of charging voltage.