- Notifications are needed for the operation of Therminal application. If user sends
SMS manually, notifications can be turned off by the means of RCP settings 7.3.8
and 7.4.8, or via settings of GSM modem (see User Manual for details).
Troubleshooting
If a run-time error occurs with the heater, RCP Can will inform you by the built-in
and additional LEDs blinking about the error code. When Plug-n-Play cable is
used for connection, additional red LED is placed inside the housing of OBD-II
connector of Plug-n-Play cable and stays visible from the driver’s side.
The number of LED’s flashes corresponds to the error code. See table 4 for the
codes description and possible solutions.
Table 4
Error
Code
Error
Description
Possible Reasons of
Error Appearance
Solutions
1
Wrong heater
configuration
The heater is not
activated in DIS
Configure the heater by Volvo
car dealer equipment
Outer temperature is
upper than +15 Celsius
degrees
The heater works only with
temperatures below +15°C. It
is the heater manufacturer's
restriction
Fuel level in the tank is
close to empty (“Fuel
Low” warning indicator
is lighting in DIS)
Refuel your vehicle
The heater is blocked
after 3 unsuccessful
starts
Try to start the heater from
DIS menu. If it not started to
burn, make a diagnostics of
the heater.
3
Battery level
is low
The module has
determined that the
battery voltage at the
heater startup or during
the heater operation is
below the specified
settings 3.1 и 3.2
Charge vehicle’s battery with
special charger (or start engine
to charge) or cancel 3.1/3.2
module’s settings
4
Time limits
exceeded
Time limit for
autonomous operation of
the heater is achieved
(with active setting 1.1)
Run the engine or cancel 1.1
module’s setting