Page 22
7.4 TEST POOL PILOT (DIAGNOSTIC MENU)
Press the MENU button, then press the
UP or DOWN arrow until “
Test Pool Pilot
” is displayed,
and press the SELECT button. The display will automatically sequence through the following displays
and then return to normal operation. You can also press the UP or DOWN arrow to scroll forwards and
backwards. Press the MENU button again to skip the remaining displays and exit back to normal
operation. The following information is displayed:
“
Salt =
####
ppm
(#.
#
g/L
)” (The optimum salt level is 3000 ppm (mg/L), 4500 ppm
(mg/L) for maximum chlorine production)
“
Add Salt
## l
bs
(##
Kg)” (The amount of salt needed to maintain 3000 ppm (mg/L))
“
Temperature
##°
F
(##°
C
)” (The temperature of the water flowing through the Tri-
sensor)
“
Cell
= ## V #.
#
A
” (The measured voltage and current sent to the cell)
“
Amp-Hrs =
######
” (The amount of current times hours of operation received by the cell)
7.5 VIEW SETUP
A program and parameter menu used to view the currently programmed settings.
Press the MENU button,
then press UP or DOWN arrow until “
View Set Up
” is displayed and
press the SELECT button. The display will automatically sequence through the following
displays and then return to normal operation. You can also press the UP or DOWN arrow to
scroll forwards and backwards. Press the MENU button again to skip the remaining displays
and exit back to normal operation. The following information is displayed:
“
Nano
” or “
Nano
+”
“
Software V
#
” (The version number of main board software)
“
Serial
#” (The Digital Nano/Nano+ serial number)
“
Display V
#
” (The version number of Display Board software)
“
Expansion V
#
” (The version number of the Expansion Board software)
“
Power level
” (The amperage driven to the cell. Set by the factory to 5A)
“
Audio alarm On/Off
” (Set by the factory to off. See page 26)
“##, ###
gallons
(
liters
)” (The pool volume programmed in
Installation Menu
;
15,000 (60,000 liters) is the factory setting. See page 23.)
“
Reverse =
#
hrs
.” (The reverse rate programmed in
Installation Menu
: 4 hrs.
is factory setting. See page 25.)
“
Temp. adjust =
#
” (The temperature adjustment variation of actual Tri-sensor
reading;
see “Calibrate Temperature” on page 23)
“
Salt
#
” (The salt calibration adjustment variation of actual Tri-sensor
reading;
see “Calibrate Salt” on page 23)
“
Purifier”
(The system mode selected. Purifier is the factory setting
–See page 26.)
“
Shutoff Temp
” (Internal temperature of the unit at which it goes into a 5 minute cool-
down period.)
“
Max temp
” (Maximum internal temperature reached)