![AutoPatch 8Y-3000 Скачать руководство пользователя страница 111](http://html1.mh-extra.com/html/autopatch/8y-3000/8y-3000_installation-and-setup-manual_3022643111.webp)
2.2 Executing Switches
Using BCS Commands
You can only execute switches with BCS commands through a device
that can connect to the serial connector on the CPU. The 8Y-XL can be
configured for both RS232 and RS422.
Note
:
In each switch command, you can enter multiple levels and
multiple output signals, but only one input signal.
To execute a switch
, enter the command using the following command
line format, where “
#
” represents any valid level, input, or output
number.
CL#I#O#T
or
CL#O#I#T
To cancel an incomplete BCS command
, enter the “
X
” command at
any time.
Examples:
BCS Command
Action
CL1I6O24T
Switches input 6 to output 24 on Level 1
CL1I6O2 4 9T
Switches input 6 to outputs 2, 4, and 9 on Level 1
CL3O2I5T
Switches input 5 to output 2 on Level 3
CL1 2I4O5 6T
Switches input 4 to outputs 5 and 6 on Levels 1 and 2
CL2I6X
Cancels the incomplete command
Note:
In each execute switch command, you can enter multiple levels
and multiple outputs
by including a space between each set of numbers
for levels or outputs
.
Operation Manual
2-5
Using BCS Commands