To execute a preset using dry contact control:
1.
Select the appropriate number of pins (1-7).
2.
Strobe pin 8 to ground (ground is pin 9).
2.6
Changing the Configuration Word
Upon powerup, the 1Y’s CPU checks the configuration word,
where the settings for the 1Y’s adjustable features are stored.
Set the adjustable features to create the best switching envi-
ronment for your system.
This section covers the following features in the configuration
word and instructions for changing them.
Control Panel Echo
Serial Status Filter
16x16 Front Panel Installed
Sync Board Enable
Serial Port Settings
SBC Polling Limit
Control Panel Configuration Scan
Control Panel Configuration
Setting the Configuration Word
2.6.1
Control Panel Echo
The control panel echo bit is the first input/output key. It al-
lows the control panel to echo the distribution matrix’s
operations when it is being controlled from an external con-
troller. This bit does not interrupt serial control operations
unless echo is required.
2-6
Chapter 2
LED1
R1
R2
P1
P2
B5
C1 C2
C3
C10
C5
U4
P1
U8
U9
C4
C13C14
R6
U19
P4
J2
U10
C6
C7
X2
C15
1Y CPU (B)
C16
U18
1022-FF-00B
C18
C17
U11
U12
C8
C9
C11
C12
U16
U14
C19
U15
U13
P5
U6
U7
U3
RP2
U1
R
T
422
232
R
T
422
232
X1
J3
1
B1
P6
AutoPatch
DIV
Technologies Inc.
X
N
1
Pin
2
3
4
5
6
7
8
9
10
figure 2.2 Dry contact pins on the CPU board
Pins 1-7 are
dry contact
lines
Pin 8 is the
active low
strobe line
Pins 9 and 10
are for digital ground
reference