3)
In Case of Motor Stops and Torque Remains
Alarm
status
Alarm type Descriptions
Causes
Troubleshooting
ee
Emergency
stop
When emergently
stopped with
emergency stop
command
1. When emergency stop
enters
1. Check EMG signal
2. Check Active Level Setting of EMG
signal
ef
Program
mode error
When ‘END’
command does
not exist at the
last step
1. If there is no ‘END’
instruction at the last step of
the program
2. If there is an empty step in
the middle of the program
1. Add ‘END’ command at last step of
program
2. Remove an empty step in middle of
a program
eg
Index mode
error
When other
instruction is
used but ‘INC',
'ABS', When index
command is not
completed due to
the stop
command
1. In case of step is not
selected
2. When running a step with
commands other than 'INC',
'ABS'
3. When entering the stop
command during driving on
index mode
1. Check where the command of the
step is ‘INC’ or ‘ABS’
2. Check that the selected step
number is correct
eh
Home
search
mode error
When failed to
find home
1. If there is no 'ORG' or
‘±Limit' input
2. if load above the set value is
not applied
(torque home search)
3. When stop command is
issued during home search
operation
1. Check if ORG signal is correctly
input (general home search)
2. Check if the ±Limit signal is
correctly input (limit home search)
3. Check if the ±Limit signal is
correctly set with the motor
rotation direction.
(CW direction: + Limit,
CCW direction: -Limit)
4. Change the value of the home
search torque parameter
(torque home search)