8.1.2.1
Reset
When driver is reset, it operates same as resupplying the power.
The parameter which is saved at atMotion is not reset.
During motor driving, it stops immediately and the driver is reset.
8.1.2.2
Start
It starts drive as program mode.
When it stops by stop instruction during driving with program mode, supplying start input, it
starts drive from the first step.
When it pauses by pause instruction during driving with program mode, supplying start input,
it starts drive from the next step of the paused one.
8.1.2.3
Start Index
It starts drive as index mode.
Start 1 step drive which selected by the combination of 6 bit (step 0 to step 5).
If the step is not selected or operating step without ABS, INC command, index mode error
occurs.
8.1.2.4
Stop
During continuous driving, it decelerates and stops the motor according to ‘Deceleration
Time 1’ parameter setting.
During program mode driving, it stops after complete the current step.
During home search, it decelerates and stops according to ‘Home Search Deceleration Time’
parameter setting. In this case, home search mode error alarm occurs.
During index mode driving, it stops driving and index mode error occurs.
8.1.2.5
EMG (Emergency)
Motor stops immediately, emergency stop alarm occurs.
The current of motor is not blocked.
During motor is stopped, EMG instruction does not run.