and re-calibrate. This may sometimes happen because of negative current, i.e.,
current coming out of the input terminals instead of into the input terminals
turbine breaker. A new voc is also acquired during a Re-Cal.
TROUBLESHOOTING
MPPT does not boot / power-up
1. Check battery connection and polarity. Reverse polarity or improper
connection will cause power-up issues.
2. Check if the battery voltage is greater than 6V. A battery voltage
less than 14V may not power up the MPPT.
MPPT is inactive
1. Is battery voltage greater than the absorb voltage set point (compensated
absorb voltage)?
If yes, the MPPT will not wake up since the battery voltage is at / above
the absorb target voltage set point.
2. Is the Turbine's voltage greater than the battery voltage by at least 2 volts?
The output voltage has to be at least 2 volts greater than the battery voltage
for the initial wakeup.
3. Check the turbine's breaker (or fuse) to ensure that the turbines breaker
(or fuse) is sized appropriately.
MPPT not producing expected power
1. Are wind conditions optimal?
Wind turbines in locations with constantly high wind speeds bring the best
return on investment. The primary consideration in a wind generator is the
average wind speed at the installation site. A different turbine will give
optimum performance at a site with average wind speeds below15mph
than one at a site with speeds in the low 20mph range.
2. Are the batteries charged? Is the MPPT in the absorbing or float stage?
If so, the MPPT will produce enough power to regulate the voltage at the
absorption or float set point voltage, therefore, requiring less power in these
modes.