16
Axess
®
Pro 1505
Installation Instructions
14. Time Clock
NOTE:
The most recent program that applies
to an output remains active until a new
program takes effect.
NOTE:
If a Time Clock program does not have
a day selected then it can not be executed.
If a Time Clock program is taking control of
the opener, then this status is displayed on
the LCD. The MAIN SCREEN and clock status
screen flashes alternatively.
The opener provides a programmable time clock which can be used to
control the Axess
®
Pro 1505 on a timed basis at various times of the week.
This section details the time clock operation and configuration.
14.1 Time Clock Operation
The time clock consists of a 7 day clock and storage for 32 programs. The
clock is powered by its own battery and therefore does not lose time when
the Axess
®
Pro 1505 is turned off. Each time clock program defines the time
of the day and the days of the week it is to run and the output function to be
executed. Any combination of the days of the week can be selected.
14.2 Time Clock Settings
The Time Clock settings are accessed by selecting the Time Clock menu
(MENU 7). Press SET (
Fig. 14.1
) to enter the menu and then PREV or NEXT
to navigate through the options.
Menu 7.1 Set Time/date
This is where the current time, date and day are displayed and set
(
Fig. 14.2
).
NOTE:
The time is in a 24 hour format and the Day of the week is not
automatically set with the date. To change the settings simply press UP or
DOWN to display the cursor and then move to the field to be changed
using the NEXT / PREV buttons. Then press OPEN/CLOSE to change the
setting and then the SET or STOP buttons to save.
Menu 7.2 View Programs
Select this menu to display or edit the Time Clock programs
(Fig. 14.3)
. When selected, program number 1 is displayed and the cursor
is shown on the program number field. The other fields shown include the
function, time and days of operation. The example
Fig. 14.4
shows that the DOOR will OPEN at 7 am on Mondays, Tuesdays,
Wednesdays, Thursdays and Fridays. Use the OPEN /CLOSE buttons to
scroll though the other programs
(Fig 14.5)
.
To edit a program, simply press the NEXT / PREV buttons to move the cursor
onto the required field and press the OPEN/CLOSE button to change the
value. To save the program settings, press SET or to exit without saving
press STOP.
MENU 7.1
Set Time/Date
PRESS
00:00:80 STD
--- 00/00/2000
MENU 7.2
View Programs
PRESS
P#01 OPEN DOOR
07:00:00 MTWTF--
Fig 14.1
Fig 14.2
Fig 14.3
Fig 14.4
The selectable functions available are:
Function
Operation
RX = Off
From the time when the program with RX = OFF is
activated, all the transmitters will be disabled.
RX = On
From the time when program with RX = ON is activated,
all the transmitters will be enabled.
Open Door
From the time when the program with OPEN DOOR is
activated, the door will open and stay open.
Stop Door
This feature will let the user activate the stop function until
the next program starts. The door will not open or close
while stop is activated.
Free Door
Release the controls from the timer.
Off
This will temporarily disable the program.
Fig 14.5