SL 90X-91X
Technical Manual
NAM-SL 90X-91X-TM-04-EN-E
With a constant view to adopting the latest technological developments, Automatic Systems reserves the right to amend the above information at any time
.
p. 39/66
9.18.
PANEL LOCKS
Figure 23 Panel locks
Test all panel locks.
Make sure the locking mechanism is not bent or damaged, making the panel hard to lock. This
problem can be caused by someone trying to force the panel in position when the panel lock is in
locked position (key in vertical position).
9.19.
MOBILE AND FIXED GLASS OBSTACLES
Visually inspect glass obstacles to detect any chips, damages, or scratches.
Check the distance between: 1) the mobile obstacle and the left panel and 2) the mobile obstacle
). There should be a 1/8-in (3.175-mm)
clearance space on both
sides of the mobile obstacle, minimum. If the clearance is too small or too large, adjust the position
of the panels.
Clean obstacles with an ammonia-free cleaning product.
9.20.
STAINLESS STEEL HOUSING
Inspect the housing for abnormal scratches, damages, or misalignment of housing components.
Clean the housing with stainless steel cleaner Sprayon (No. 50050), or equivalent.