10. TERMINAL AND INPUT/OUTPUT ALLOCATION
Board VB3406A:
Connector Terminal Allocation
M1
1
+24 VDC
2
+12
VDC
3
0
V
M2 1 0
V
2
+12
VDC
3
+24
VDC
4
Bridge
tension
5
+VDC
M3 1 +12
VDC
2
0
V
3
/
4
/
M4 1 0
V
2 Power
input
3 +12
VDC
4 +RS485
5 -RS485
M5 1 0
V
2
0
V
3
+24
VDC
4
+12
VDC
5
+V
CL
6
-V
CL
7
Distinct emergency opening: normally closed contact
8
Distinct emergency opening: normally open contact
9
Common
10
Normally closed contact
11
Normally open contact
12
Common
13
Normally closed contact
14
Single-presence
detection:
Reset
15
Common
16
Normally
closed
17
Presence detector: Reset
18
Common
CN1 1 See
wiring
diagram
2
See
wiring
diagram
3
See
wiring
diagram
4
See
wiring
diagram
5
See
wiring
diagram
CN2A 1
See
wiring
diagram
2
See
wiring
diagram
CN2B 1
See
wiring
diagram
2
See
wiring
diagram
3
See
wiring
diagram
4
See
wiring
diagram
CN3 1 +12
VDC
2
Opening
button
3
Red
pictogram
4
Green
pictogram