5.2. Problems and troubleshooting (alarms)
SYMPTOM
CAUSE
SOLUTION
The 2 LEDs of board
VB3406 do not blink.
Communication is interrupted
between the electronic boards.
Check connections.
Message displayed
on the console
The breaker powering the
booth is open.
Close the breaker in the electrical panel.
The breaker powering the
booth is not powered on.
Contact the utility provider and check the
characteristics of the electrical power.
The connection between the
breaker and board VB4313 is
defective.
Check the condition of the cable and
ensure the cable is connected at the right
place.
The connection between
power supply VB4313 and
board VB3405 is defective.
Check the condition of the cable and
ensure the cable is connected at the right
place (see wiring diagram).
Power supply VB4313
defective.
Replace.
Message displayed
on the console
+
Voice message
telling the user to exit
and to remove all
metal objects.
Metal objects detected on the
user (only if the optional metal
detector is activated: SYSTEM
> PROGRAM > FUNCTIONS).
The user must exit the booth, allow the
first door to close, and remove any metal
objects from his or her person before
returning to the front of the metal
detector.
The operator can cancel the alarm by
pressing button 3 (RESET) to allow the
normal cycle to continue.
M.D. ALARM
MAINS FAILURE
500 mA
F5
RL4
RL5
RL6
RL7
J1
RL8
RLY1
RLY2
RL2
M5
TR1
CN16
1 2
J4
J5
RL1
CNAUX
CNK
CPU
SW2
SW1
J2
JP6
JP5
JP11
JP12
JP13
JP8
5
1
5
1
2 1
4
1
6
1
6
1
JP2
JP1
VB 2406 B
1
1
CNMA
CNMB
VB 2406 B
1
1
CNMC
CNMD
MOT1
MOT2
2 A
F1
10 A
F2
10 A
F3
10 A
F4
1 3
M1
1 5
M2